Objective: The aim of this study was to examine the test-retest reliability, internal consistency, and floor and ceiling effects of a Norwegian version of the Neurological Fatigue Index for Stroke (NFI-Stroke).

Method: To evaluate the psychometric properties of the NFI-Stroke, persons with stroke were recruited. Inclusion criteria were: ≥18 years; a performance of ≥4 seconds on the Clock-Drawing Test; and participants had to speak and understand Norwegian. Test-retest reliability, internal consistency, and floor and ceiling effects were evaluated with Spearman's rho, Weighted Kappa, Cronbach's Alpha, corrected total-item correlation, percentage of the total score, and responses to each item.

Result: Of 82 eligible, 66 respondents were included in the project. NFI-Stroke has a test-retest reliability of 0.89, 0.89, and 0.87 with Spearman's rho and 0.55-0.78 with Weighted Kappa. For the subgroup chronic stroke, Spearman's rho was 0.89, 0.86, and 0.93, and Weighted Kappa was 0.61-0.91. For the subgroup sub-acute stroke, Spearman's rho was 0.48, 0.55, and 0.51, and Weighted Kappa was 0.02-0.54. Cronbach's Alpha was 0.90. For the physical subscale, alpha was 0.89, and for the cognitive subscale 0.74. Corrected total-item correlation for NFI-Stroke was 0.50-0.78, 0.55-0.79 for the physical subscale, and 0.46-0.60 for the cognitive subscale. None scored the highest nor lowest possible score of the questionnaire.

Conclusion: NFI-Stroke has high test-retest reliability, and high internal consistency with neither floor nor ceiling effects for persons with stroke. The questionnaire may be useful both in general rehabilitation in institutions as well as in the municipal health services.

Download full-text PDF

Source
http://dx.doi.org/10.1080/09593985.2020.1825581DOI Listing

Publication Analysis

Top Keywords

test-retest reliability
16
spearman's rho
16
weighted kappa
16
internal consistency
12
consistency floor
12
floor ceiling
12
ceiling effects
12
neurological fatigue
8
fatigue stroke
8
norwegian version
8

Similar Publications

Objective: To determine the correlation among five different types of tumor regression grading (TRG) systems. Test-retest reliability analyses were conducted at two time points to assess the internal validity and consistency of these five TRG systems.

Methods: A test-retest study was performed in 34 pathologically confirmed rectal adenocarcinoma specimens.

View Article and Find Full Text PDF

Utility of a C-Spirulina Stable Isotope Gastric Emptying Breath Test in Diabetes Mellitus.

Neurogastroenterol Motil

January 2025

Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA.

Background: The carbon-13 spirulina gastric emptying breath test (GEBT) is approved to identify delayed, but not accelerated, gastric emptying (GE). We compared the utility of the GEBT to scintigraphy for diagnosing abnormal GE in patients with diabetes mellitus.

Methods: Twenty-eight patients with diabetes ate a 230-kcal test meal labeled with technetium 99 m and C-spirulina, after which 10 scintigraphic images and breath samples (baseline, 15, 30, 45, 60, 90, 120, 150, 180, 210, and 240 min) were collected on 2 occasions 1 week apart.

View Article and Find Full Text PDF

Purpose: The H reflex recruitment curve represents the gold standard for quantifying changes in spinal circuitries. However, there is no agreement on how many stimulations should be applied for each parameter. Thus, we explored the impact of varying the number of stimulations (3, 6, 9, 12 and 15 stimuli per intensity) on between-day reliability of soleus H reflex.

View Article and Find Full Text PDF

Deep Learning Superresolution for Simultaneous Multislice Parallel Imaging-Accelerated Knee MRI Using Arthroscopy Validation.

Radiology

January 2025

From the Department of Radiology, Division of Musculoskeletal Radiology, NYU Grossman School of Medicine, 660 1st Ave, 3rd Fl, Rm 313, New York, NY 10016 (S.S.W., J.V., R.K., E.H.P., J.F.); Department for Diagnostic and Interventional Radiology, Eberhard Karls University Tübingen, University Hospital Tübingen, Tübingen, Germany (S.S.W.); Department of Radiology, University Hospital Basel, Basel, Switzerland (J.V.); Department of Radiology, Hospital do Coraçao, São Paulo, Brazil (T.C.R.); Academic Surgical Unit, South West London Elective Orthopaedic Centre (SWLEOC), London, United Kingdom (D.D.); Department of Radiology, Balgrist University Hospital, Zurich, Switzerland (B.F.); Department of Radiology, Jeonbuk National University Hospital, Jeonju, Republic of Korea (E.H.P.); Research Institute of Clinical Medicine of Jeonbuk National University, Biomedical Research Institute of Jeonbuk National University Hospital, Jeonju, Republic of Korea (E.H.P.); Medscanlagos Radiology, Cabo Frio, Brazil (A.S.); Centre for Data Analytics, Bond University, Gold Coast, Australia (S.E.S.); Siemens Healthineers AG, Erlangen, Germany (I.B.); and Siemens Medical Solutions USA, Malvern, Pa (G.K.).

Background Deep learning (DL) methods can improve accelerated MRI but require validation against an independent reference standard to ensure robustness and accuracy. Purpose To validate the diagnostic performance of twofold-simultaneous-multislice (SMSx2) twofold-parallel-imaging (PIx2)-accelerated DL superresolution MRI in the knee against conventional SMSx2-PIx2-accelerated MRI using arthroscopy as the reference standard. Materials and Methods Adults with painful knee conditions were prospectively enrolled from December 2021 to October 2022.

View Article and Find Full Text PDF

Exploration of the dynamics of otic capsule and intracochlear pressure: Numerical insights with experimental validation.

J Acoust Soc Am

January 2025

Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland.

The otic capsule and surrounding temporal bone exhibit complex 3D motion influenced by frequency and location of the bone conduction stimulus. The resultant correlation with the intracochlear pressure is not sufficiently understood, thus is the focus of this study, both experimentally and numerically. Experiments were conducted on six temporal bones from three cadaver heads, with BC hearing aid stimulation applied at the mastoid and classical BAHA locations across 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!