Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aim: The present study analyzes in depth the impact of different calcification patterns on disturbances of the conduction system in transcatheter aortic valve replacement (TAVR) patients.
Methods And Results: A total of 169 preprocedural TAVR multislice computed tomography scans from consecutive transfemoral (TF) TAVRs performed between 2014 and 2017 using either Edwards SAPIEN or Medtronic Evolut R valves were retrospectively evaluated. The volume, distribution, and orientation of annular and valvular aortic valve calcification were measured and their impact on postoperative conduction disturbances was determined using linear and logistic regression analyses. The total volume of calcification and distribution at the aortic annulus or valve did not influence the conduction system. Oval calcification of the left aortic cusp was independently associated with an elevated risk for an increase in atrioventricular block degree (+0.6, p = 0.03). Moreover, orthogonal calcifications at the level of the aortic annulus were associated with an increased risk for QRS prolongation (+26 ms, p = 0.004) and an increased risk for permanent pacemaker implantation (OR 4.3, p = 0.03) after TF TAVR. This was more pronounced in patients undergoing TF TAVR using a balloon-expandable Edwards SAPIEN 3 valve (QRS +38.195 ms, p < 0.001; OR permanent pacemaker 15.48, p = 0.013).
Conclusion: Orthogonal annular calcification confers an increased risk for conduction disturbances after TAVR. This is even more pronounced after implantation of balloon-expandable valves.