Aim: To investigate the association between visit-to-visit HbA1c variability and the risk of cardiovascular disease in patients with type 2 diabetes.

Materials And Methods: We performed a retrospective cohort study of 29 260 patients with at least four HbA1c measurements obtained within 2 years of their first diagnosis of type 2 diabetes. Different HbA1c variability markers were calculated, including the standard deviation (SD), coefficient of variation (CV) and adjusted SD. Cox proportional hazards regression models were used to estimate the association of these HbA1c variability markers with incident cardiovascular disease.

Results: During a mean follow-up of 4.18 years, a total of 3746 incident cardiovascular disease cases were diagnosed. Multivariate-adjusted hazard ratios for cardiovascular disease across the first, second, third and fourth quartiles of HbA1c SD values were 1.00, 1.30 (95% confidence interval [CI] 1.18-1.42), 1.40 (95% CI 1.26-1.55) and 1.59 (95% CI 1.41-1.77) (P for trend <.001), respectively. When we utilized HbA1c CV and adjusted HbA1c SD values as exposures, similar positive associations were observed. HbA1c variability was also associated with the risk of first and recurrent severe hypoglycaemic events. A mediating effect of severe hypoglycaemia was observed between HbA1c variability and incident cardiovascular disease.

Conclusions: Large visit-to-visit HbA1c variability is associated with an increased risk of cardiovascular disease in patients with type 2 diabetes. Severe hypoglycaemia may mediate the association between HbA1c variability and incident cardiovascular disease.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9092602PMC
http://dx.doi.org/10.1111/dom.14201DOI Listing

Publication Analysis

Top Keywords

hba1c variability
16
cardiovascular disease
16
association visit-to-visit
8
visit-to-visit hba1c
8
variability risk
8
risk cardiovascular
8
disease patients
8
patients type
8
type diabetes
8
variability markers
8

Similar Publications

Introduction: The effect and mechanism of skipping breakfast on glycemic control in type 2 diabetes mellitus (T2DM) in Asian-Indians is unknown.

Methods: Cross-over, within-group study recruiting 5 habitual breakfast eaters (BE) and 5 habitual breakfast skippers (BS) with uncontrolled T2DM (HbA1c 7-9%). Patients underwent testing after three days of following their usual breakfast habits and after seven days of crossing over to the other arm.

View Article and Find Full Text PDF

Background: Comprehensive management of acute coronary syndrome (ACS) requires seamless treatment across institutions, including intensive care centers and local clinics. However, maintaining guideline-directed medical therapy remains challenging. One promising option to improve the situation may be the implementation of regional collaborative clinical pathways.

View Article and Find Full Text PDF

In most cases, the diagnosis of diabetes in animal models is based solely on blood glucose levels. While hemoglobin A1c (HbA1c) is widely used in the diagnosis of diabetes in humans, it is rarely measured in mice in diabetes research. This is thought to be because there are no established reference values for mouse HbA1c, as well as the fact that there are very few reports on the variability and reproducibility of measurements taken using different devices.

View Article and Find Full Text PDF

Background: This study aimed to compare the economic value of intermittent-scanning continuous glucose monitoring (isCGM) with self-monitoring of blood glucose (SMBG) in adults with type 1 diabetes (T1D).

Methods: Participants were placed on either an isCGM or SMBG arm for 84 days, in a randomized, crossover setup with a 28-day washout period. Clinically relevant hypoglycemia (<54 mg/dL) and severe hypoglycemia (SH) risks were calculated by analyzing the data from isCGM.

View Article and Find Full Text PDF

Unlabelled: The hybrid closed-loop (HCL) system, Medtronic MiniMed 770G, has been available for use by Japanese individuals with type 1 diabetes mellitus since 2021. The aim of this study was to evaluate the effect of its use on glycemic variability and quality of life (QOL) in this population. This multicenter, open-label, prospective observational study included 14 Japanese individuals with type 1 diabetes mellitus treated with MiniMed 640G.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!