Purpose: The BIOLUX P-III registry was initiated to further assess the safety and efficacy of the Passeo-18 Lux drug-coated balloon (DCB) in infrainguinal lesions in a real-world environment and in prespecified risk groups.

Materials And Methods: BIOLUX P-III is a prospective, global, all-comers registry with patients treated under real-world conditions. We herein report 24-month results of the prespecified subgroup of 151 patients with 185 below-the-knee (BTK) lesions. The primary safety and efficacy endpoints were freedom from major adverse events (a composite of freedom from device and procedure mortality through 30 days, major target limb amputation and clinically driven target lesion revascularization) at 6 months and freedom from clinically driven target lesion revascularization (FfTLR) at 12 months.

Results: At baseline, 76.0% of patients had critical limb ischemia and 48.9% of lesions were TASC C or D lesions. Technical success was achieved in 97.8%, and bailout stenting was required in 1.1%. Freedom from major adverse events was 86.2% [95% CI 79.4; 90.8] at 6 months, and FfTLR was 90.9% [95% CI 85.2; 94.4] at 12 months. At 24 months, FfTLR was 90.9% [95% CI 85.2; 94.4], freedom from major amputation was 90.1% [95% CI 83.9, 94.0], and overall survival was 79.2% [70.7, 85.5]. There was a significant clinical improvement (mean Rutherford class improvement of - 2.9 ± 1.9, p < 0.0001) and an improvement in pain (mean improvement on Wong-Baker Faces Pain Scale of - 2.7 ± 2.9, p < 0.0001).

Conclusions: In this real-world DCB registry, 24-month outcomes of Passeo-18 Lux demonstrated safety and efficacy in BTK lesions with high patency rates and sustained clinical improvements at 24 months.

Trial Registration: NCT02276313.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00270-020-02586-3DOI Listing

Publication Analysis

Top Keywords

biolux p-iii
12
freedom major
12
all-comers registry
8
safety efficacy
8
major adverse
8
adverse events
8
clinically driven
8
driven target
8
target lesion
8
lesion revascularization
8

Similar Publications

Article Synopsis
  • This study aimed to evaluate the mid-term results of drug-coated balloons (DCBs) in treating infrainguinal peripheral arterial disease (PAD) in patients with dyslipidemia compared to those without.
  • It analyzed data from 876 patients involved in the BIOLUX P-III study and found no differences in major adverse events but noted that patients with dyslipidemia had significantly higher rates of clinically driven target lesion revascularization (CD-TLR) and target vessel revascularization (TVR) at 6, 12, and 24 months.
  • The findings suggest that while dyslipidemia does not affect overall safety outcomes, it may lead to less favorable revascularization results when treated with Passeo
View Article and Find Full Text PDF

Purpose: To investigate the clinical performance and safety of the Passeo-18 Lux drug-coated balloon (DCB) in complex femoropopliteal Trans-Atlantic Inter-Society Consensus (TASC) C and D lesions in an all-comers patient population.

Material And Methods: Data from BIOLUX P-III SPAIN, a prospective, national, multicenter, postmarket all-comers registry conducted from 2017 to 2019, and a matching long lesion subgroup from the BIOLUX P-III All-Comers global registry conducted from 2014 to 2018 were pooled for analysis. The primary safety end point was freedom from major adverse events (MAEs) at 6 months, and the primary performance end point was freedom from clinically driven target lesion revascularization (fCD-TLR) at 12 months, both adjudicated by an independent clinical events committee.

View Article and Find Full Text PDF

Purpose: To evaluate the use of drug-coated balloons in a real-world patient population with peripheral arterial disease and analyse the impact of sex on mid-term outcomes following their utilisation.

Methods: The BIOLUX P-III is a prospective, international, multi-centre, registry of patients with infra-inguinal lesions treated using the Passeo-18 Lux, a drug-coated balloon. Our study is a 24-month subgroup analysis of these patients; primary endpoints were freedom from major adverse events and clinically driven target lesion re-vascularisation within 12 months post-intervention.

View Article and Find Full Text PDF

Background: Results from the BIOLUX P-III registry have demonstrated favourable outcomes of (Biotronik®, Buelach, Switzerland) drug-coated balloon in treating obstructive infrainguinal peripheral artery disease, but it has not been established if Asians would benefit to the same extent as non-Asians.

Methods: A subgroup analysis was performed on the 24-month data comparing the Asian cohort (AC) to non-Asian cohort (NAC).

Results: AC included 49 patients with 77 lesions.

View Article and Find Full Text PDF

Background: Recent meta-analyses have raised concerns about mortality with paclitaxel drug-coated balloons (DCB). This pooled, patient-level analysis of the BIOLUX P-I, P-II, and P-III studies was performed to evaluate the safety and efficacy of Passeo-18 Lux DCB.

Materials And Methods: Individual patient-level demographic, clinical, diagnostic, and procedural data from the BIOLUX P-I, BIOLUX P-II, and BIOLUX P-III studies were pooled in a common database.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!