Objective: To evaluate the relative incidence of cardiogenic and septic shock in term neonates and identify findings that help differentiate the two entities.
Study Design: We conducted a retrospective chart review of term neonates presenting to British Columbia Children's Hospital (BCCH) with decompensated shock of an undiagnosed etiology between January 1, 2008 and January 1, 2013. Charts were reviewed to determine the underlying diagnoses of all neonates meeting our inclusion criteria. Patients were categorized as having septic, cardiogenic, or other etiologies of shock. We then evaluated potential demographic, clinical, and biochemical parameters that could help differentiate between septic and cardiogenic shock.
Results: Cardiogenic shock was more common than septic shock (relative risk=1.53). A history of cyanosis was suggestive of cardiogenic shock (positive likelihood ratio, LR+=3.2 and negative likelihood ratio, LR-=0.4). Presence of a murmur or gallop (LR+=5.4, LR-=0.3), or decreased femoral pulses (LR+=5.1, LR-=0.5) on physical exam were also suggestive of cardiogenic shock as was cardiomegaly on chest x-ray (LR+=4.9, LR-=0.5). Notably, temperature instability (LR+=0.7, LR-=1.8) and white blood cell count elevation or depression (LR+=0.8, LR-=1.1) were all poor predictors of septic shock.
Conclusion: Cardiogenic shock is a more common cause of decompensated shock than septic shock. A history of cyanosis, murmur or gallop, or decreased femoral pulses on exam and cardiomegaly on chest x-ray are useful indicators of cardiogenic shock. In evaluating the neonate with decompensated shock, early consideration for Cardiology consultation and interventions to treat the underlying condition is warranted.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7492622 | PMC |
http://dx.doi.org/10.1093/pch/pxz078 | DOI Listing |
Clin Toxicol (Phila)
January 2025
Pediatric Intensive Care Unit, Emergency Department, Bambino Gesù Children's Hospital, IRCCS, Rome, Italy.
Introduction: Veno-arterial extracorporeal membrane oxygenation is frequently considered and implemented to help manage patients with cardiogenic shock from acute poisoning. However, utilization of veno-venous extracorporeal membrane oxygenation in acutely poisoned patients is largely unknown.
Method: We conducted a retrospective study analyzing the epidemiologic, clinical characteristics and survival of acutely poisoned patients placed on veno-venous extracorporeal membrane oxygenation using the Extracorporeal Life Support Organization registry.
ASAIO J
January 2025
From the Department of Cardiology, Université Paul Sabatier - Toulouse III, Toulouse, France.
ESC Heart Fail
January 2025
Division of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, University of Düsseldorf, Düsseldorf, Germany.
Aims: Transcatheter edge-to-edge repair of the mitral valve (M-TEER) is known for its low complication rates. However, the optimal level and duration of post-procedural care remain unclear. This study aimed to identify the specific timeframe of post-procedural complications following M-TEER.
View Article and Find Full Text PDFJ Cardiothorac Surg
January 2025
Echocardiography and Vascular Ultrasound Center, The First Affiliated Hospital, Zhejiang University School of Medicine, 79 Qingchun Road, Hangzhou, 310003, China.
Background: Interventricular septal dissection is a critical disease characterized by the separation of the intraventricular septum into two layers, forming an intermediate layer with a cystic cavity that communicates with the root of the aorta or ventricle. It has low morbidity and high mortality rates.
Case Presentation: Case 1: A 58-year-old male with a history of hypertension and smoking presented to a local hospital due to chest tightness and pain for 4 days.
Ann Biomed Eng
January 2025
BioCardioLab, Fondazione Toscana G. Monasterio, 54100, Massa, Italy.
Extracorporeal Membrane Oxygenation (ECMO) is a modality of extracorporeal life support which allows temporary support in cases of cardiopulmonary failure and cardiogenic shock. This study presents a valveless pump that works by the Liebau effect as a possible pumping system in ECMO circuits, replacing the current roller and centrifugal pumps. For this purpose, a mock circulatory loop emulating the haemodynamic of the right part of the heart has been constructed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!