Optic nerve sheath diameter (ONSD) sonography is a reliable method for evaluation of intracranial pressure, yet there is a lack of reliable normal values. In the study described here, we established normal ONSD values in three different age groups and both sexes. One hundred eighty-seven volunteers without central nervous system disease were enrolled in this prospective study. ONSD measurements were taken in volunteers in the supine and upright positions and after application of positive end-expiratory pressure (PEEP). Normal ONSD values were 4.9-5.3 mm (patient age range: 20-85), with significant differences between men and women (p < 0.001). ONSD values increased with age (∆ = 0.34 mm, p < 0.001). There were no differences compared with the upright position but application of PEEP led to significantly increased ONSD values (∆ = 0.21 mm, p = 0.008). ONSD values increased with age, correlated well with the width of the third ventricle, were significantly lower in the female cohort and quickly responded to PEEP, especially in women.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultrasmedbio.2020.08.025 | DOI Listing |
J Clin Neurosci
January 2025
Department of Ultrasonic Medicine, Fudan University Affiliated Huashan Hospital, No 12, Middle Wulumuqi Road, Shanghai 200040, China. Electronic address:
Objective: This prospective observational study aimed to assess the effectiveness of B-mode ultrasound, color-coded Doppler, and shear-wave elastography in predicting intracranial pressure (ICP) and their capability to evaluate the efficacy of ICP lowering therapy.
Materials And Methods: Forty-eight neuro-critical care patients were enrolled and categorized into 2 groups based on ICP measurements obtained through external ventricular drainage: the intracranial hypertension (IH) and normal ICP groups. The optic nerve (ON) sheath diameter (ONSD), end diastolic velocity, peak systolic velocity, resistance index of the central retinal artery (CRA), and Young's modulus (YM) of the ON were recorded after external ventricular drainage placement and following ICP lowering treatment in the IH group.
Front Pediatr
January 2025
Department of Pediatrics, The Affiliated Yangming Hospital of Ningbo University, Yuyao People's Hospital, Yuyao Branch of the Second Affiliated Hospital of Zhejiang University School of Medicine, Ningbo, China.
Introduction: Increased intracranial pressure (ICP) is common with viral encephalitis in children which is associated with complications and prognosis. The optic nerve sheath diameter (ONSD) is a new indicator for the assessment of intracranial pressure using ultrasound, CT scan and MRI imaging. Given the influence of physical development on ONSD size in children, we expect more accurate assessment of intracranial pressure with ONSD/ETD (eyeball transverse diameter) ratio by ultrasound.
View Article and Find Full Text PDFLupus Sci Med
January 2025
Physical Medicine, Rheumatology & Rehabilitation, School of Medicine, Tanta University, Tanta, Egypt.
Objective: Evaluating the potential role of neuromuscular ultrasonography (NMUS) in assessing optic nerve affection in patients with systemic lupus erythematosus (SLE), compared with healthy controls and other conventional strategies in diagnosing optic neuropathy.
Methods: We conducted an observational cross-sectional study comparing patients with SLE and a healthy group. We measured the optic nerve diameter (OND) and optic nerve sheath diameter (ONSD) and calculated the OND/ONSD ratio and side-to-side difference.
A A Pract
January 2025
Département d'Anesthésie, Hôpital Antoine Béclère, APHP.Université Paris-Saclay, Clamart, France.
We describe a patient with severe Arnold Chiari Malformation and syringomyelia who underwent gynecological laparoscopy in an emergency context; no brain imaging was available. We here report the successful use of optic nerve sheath diameter (ONSD) and middle cerebral artery (MCA) velocity measurements as surrogate monitoring for cerebral blood flow and intracranial pressure, respectively. MCA velocity was low when assessed after peritoneal insufflation and ONSD increased to 6.
View Article and Find Full Text PDFUltrasound J
January 2025
Faculdade de Medicina da Universidade de Lisboa, Lisbon, Portugal.
Background: There are significant discrepancies in the optic nerve sheath diameter (ONSD) reported in the literature. We aimed to determine the ultrasonographic imaging features of ONSD and ophthalmic vessels in a healthy population, using a standardized protocol, and to estimate the effect of demographics and positioning changes on imaging measurements.
Methods: We measured the mean values of the ONSD in supine and sitting position and the Doppler imaging parameters of the ophthalmic, central retinal and short posterior ciliary arteries.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!