Numerical study on the effect of stent shape on suture forces in stent-grafts.

J Mech Behav Biomed Mater

GRANTE - Department of Mechanical Engineering, Federal University of Santa Catarina, Florianópolis, SC, Brazil; LEBm - University Hospital, Federal University of Santa Catarina, Florianópolis, SC, Brazil. Electronic address:

Published: October 2020

Second-generation stent-grafts (SGs) have addressed many of the mechanical problems reported for first-generation endoprostheses, such as graft tear and stent rupture; however, suture wear and detachment due to pulsatile fatigue remains an issue. Numerical studies on the mechanical behavior of these endoprostheses usually model the attachment between stents and graft as a continuous ''tie'' constraint, which does not provide information on the mechanical loads acting on individual sutures. This paper presents a suitable approach for Finite Element (FE) simulations of SGs which allows for a qualitative evaluation of the loads acting on sutures. Attachment between stents and graft is modeled as rigid beams at discrete locations of the endoprostheses, and the reaction forces on the beams are analyzed. This modeling strategy is employed for four different SG models (two Z-stented commercial models and two circular-stented models) subjected to a severe 180° U-bend, followed by intraluminal pressurization. Results show that, for all models, the majority of sutures is experiencing fluctuating forces within a cardiac cycle (between 80 and 120 mmHg), which points to pulsatile fatigue as potential failure mode. In addition, the highest loads are concentrated in kinks and, for Z-stented models, at the apexes of stents. Moreover, suture loads for circular-stented models are lower than for Z-stented models, indicating better resistance to suture detachment. All these observations are in line with experimental results published in the literature, and, therefore, the procedure herein proposed may serve as a valuable tool in the development of new SG models with better suture resistance to pulsatile wear and fatigue.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2020.103852DOI Listing

Publication Analysis

Top Keywords

pulsatile fatigue
8
attachment stents
8
stents graft
8
loads acting
8
models
8
circular-stented models
8
z-stented models
8
suture
5
numerical study
4
study stent
4

Similar Publications

Background: Hypoglossal canal dural arteriovenous fistulas (HCDAVFs) are a relatively rare subtype of dural arteriovenous fistula (dAVF), representing 3%-5% of all dAVFs. The complex angio- and venous architecture predisposed to numerous anastomoses and nearby anatomical structures, including the posterior fossa sinuses and cranial nerves, can complicate both the diagnosis and treatment of these lesions.

Observations: The authors describe the case of HCDAVF in a 74-year-old male who presented with pulsatile tinnitus (PT) lasting 3 months and significant fatigue, headaches, and dizziness.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigated how stenting affects the length, shape, and movement of the patent ductus arteriosus (PDA) in patients reliant on this vessel for blood flow to the lungs.
  • Involved 12 patients with congenital heart issues, revealing significant shortening (26%) and straightening of the PDA after stenting, with notable reductions in curvature.
  • Findings emphasize the importance of precise stent sizing to avoid complications and offer insights for better device design for congenital heart patients, especially in neonates.
View Article and Find Full Text PDF

In Silico Evaluation of In Vivo Degradation Kinetics of Poly(Lactic Acid) Vascular Stent Devices.

J Funct Biomater

May 2024

Biomechanics Laboratory, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China.

Biodegradable vascular stents (BVS) are deemed as great potential alternatives for overcoming the inherent limitations of permanent metallic stents in the treatment of coronary artery diseases. The current study aimed to comprehensively compare the mechanical behaviors of four poly(lactic acid) (PLA) BVS designs with varying geometries via numerical methods and to clarify the optimal BVS selection. Four PLA BVS (i.

View Article and Find Full Text PDF

Introduction: Multiple sclerosis (MS) is an immune-mediated, neurodegenerative disease of the central nervous system. Fatigue represents one of the most prevalent and limiting symptoms of MS, and is associated with vascular dysfunction, notably increased arterial stiffness.

Objective: This study examined the relationship between arterial stiffness and perceived fatigue in persons with MS.

View Article and Find Full Text PDF

Background: Afatinib (BIBW2992; Gilotrif®) is a selective and irreversible inhibitor of the epidermal growth factor receptor (ErbB; EGFR) family. It inhibits EGFR, HER2, and HER4 phosphorylation, resulting in tumor growth inhibition and regression. This phase I dose-escalation trial of pulsatile afatinib examined the safety, drug penetration into the central nervous system, preliminary antitumor activity, and recommended phase II dose in patients with progressive or recurrent brain cancers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!