During the process of seizures, the addition of low-frequency magnetic fields has been proved to be an effective method to suppress epileptic discharges. However, whether adding magnetic fields before the appearance of epileptic discharges can produce this inhibition has not been studied. In the present study, we first constructed epilepsy models on brain slices by perfusing them with Mg-free artificial cerebrospinal fluid (aCSF). The events of seizures evolved from inter-ictal epileptiform discharges (IIDs) to inter-epileptiform discharges (IDs). Combined with the multi-electrode array platform, we designed a flexible moving coil to generate a 0.5 Hz magnetic field on the brain slices. Using this method, we added the magnetic fields to brain slices for 30 min before epileptiform discharges were induced. The experimental results demonstrated that although the priming magnetic fields could not completely inhibit epileptiform discharges, they can significantly reduce the frequency of IDs and increase the frequency of IIDs in the CA3 region of the hippocampal slices. In the control group, the rates of IDs and IIDs were 0.0024 ± 0.0006 Hz and 0.0138 ± 0.0043 Hz, respectively, while in the magnetic stimulation group, the rates were 0.0012 ± 0.0004 Hz and 0.0251 ± 0.0067 Hz. Moreover, the results indicated that changing the frequency of interictal discharges did not affect ictogenesis. The results demonstrated that the priming magnetic fields had a certain weakening effect on the frequency of IDs, which was achieved by reducing the signal propagation speed and increasing the excitability threshold of hippocampal neurons.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.eplepsyres.2020.106464 | DOI Listing |
Heliyon
January 2025
BCN MedTech, Department of Information and Communication Technologies, Universitat Pompeu Fabra, Barcelona, Spain.
Deformable image registration is a cornerstone of many medical image analysis applications, particularly in the context of fetal brain magnetic resonance imaging (MRI), where precise registration is essential for studying the rapidly evolving fetal brain during pregnancy and potentially identifying neurodevelopmental abnormalities. While deep learning has become the leading approach for medical image registration, traditional convolutional neural networks (CNNs) often fall short in capturing fine image details due to their bias toward low spatial frequencies. To address this challenge, we introduce a deep learning registration framework comprising multiple cascaded convolutional networks.
View Article and Find Full Text PDFBiomed Opt Express
January 2025
State Key Laboratory of Advanced Optical Communication Systems and Networks, School of Electronics, and Center for Quantum Information Technology, Peking University, Beijing 100871, China.
Optically-pumped magnetometer (OPM) has been of increasing interest for biomagnetic measurements due to its low cost and portability compared with superconducting quantum interference devices (SQUID). Miniaturized spin-exchange-relaxation-free (SERF) OPMs typically have limited bandwidth (less than a few hundred Hertz), making it difficult to measure high-frequency biomagnetic signals such as the magnetocardiography (MCG) signal of the mouse. Existing experiments mainly use SQUID systems to measure the signal.
View Article and Find Full Text PDFDirac-vortex cavities have single-mode emitting, scalable mode areas, arbitrary mode degeneracies, and vector-beam vertical emission, which attract more and more researchers' attention. Here, we demonstrate the single-mode of two-dimensional transverse magnetic (TM) Dirac-vortex topological cavity modes that are not only generally available for high power topological surface-emitting lasers (TCSEL) but also are one of the excellent candidates for refractive index sensors. The principle for winding number is studied, and the scaling laws are shown with cavity mode diameters.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Institute of Humanoid Robots, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, P.R. China.
Magneto-responsive soft actuators hold significant promise in soft robotics due to their rapid responsiveness and untethered operation. However, controlling their deformations presents challenges because of their inherent flexibility and high degrees of freedom. Here, we present a magnetically driven bistable dome-shaped soft actuator that simplifies deformation by limiting it to two distinct states.
View Article and Find Full Text PDFWater Sci Technol
January 2025
School of Civil Engineering and Architecture, University of Jinan, Jinan 250022, China E-mail:
Ultrafiltration membranes are widely used in the treatment of surface water. However, membrane fouling is a core issue that needs to be addressed in its application. Magnetotactic bacteria (MTB) show early film-forming and magnetotactic behaviour in the presence of external magnetic fields.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!