Background: Subcutaneous nerve stimulation (ScNS) delivered directly to large subcutaneous nerves can be either antiarrhythmic or proarrhythmic, depending on the stimulus output.

Objective: The purpose of this study was to perform a prospective randomized study in a canine model of persistent AF to test the hypothesis that high-output ScNS using blindly inserted subcutaneous electrodes can reduce ventricular rate (VR) during persistent atrial fibrillation (AF) whereas low-output ScNS would have opposite effects.

Methods: We prospectively randomized 16 male and 15 female dogs with sustained AF (>48 hours) induced by rapid atrial pacing into 3 groups (sham, 0.25 mA, 3.5 mA) for 4 weeks of ScNS (10 Hz, alternating 20-seconds ON and 60-seconds OFF).

Results: ScNS at 3.5 mA, but not 0.25 mA or sham, significantly reduced VR and stellate ganglion nerve activity (SGNA), leading to improvement of left ventricular ejection fraction (LVEF). No differences were found between the 0.25-mA and sham groups. Histologic studies showed a significant reduction of bilateral atrial fibrosis in the 3.5-mA group compared with sham controls. Only 3.5-mA ScNS had significant fibrosis in bilateral stellate ganglions. The growth-associated protein 43 (GAP43) staining of stellate ganglions indicated the suppression of GAP43 protein expression in the 3.5-mA group. There were no significant differences of nerve sprouting among all groups. There was no interaction between sex and ScNS effects on reduction of VR and SGNA, LVEF improvement, or results of histologic studies.

Conclusion: We conclude that 3.5-mA ScNS with blindly inserted electrodes can improve VR control, reduce atrial fibrosis, and partially improve LVEF in a canine model of persistent AF.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2020.09.009DOI Listing

Publication Analysis

Top Keywords

blindly inserted
12
canine model
12
model persistent
12
subcutaneous nerve
8
nerve stimulation
8
inserted electrodes
8
ventricular rate
8
persistent atrial
8
atrial fibrillation
8
scns
8

Similar Publications

Application of Gastric Tube Decompression for Rapid Tip Positioning in Bedside Blind Insertion of Nasoenteric Tubes.

J Multidiscip Healthc

January 2025

Department of Hepatobiliary Pancreatic Surgery, China-Japan Friendship Hospital, Beijing, 100029, People's Republic of China.

Objective: This study aims to examine the efficacy of gastric tube decompression in rapid tip positioning during bedside blind insertion of nasoenteric tubes.

Methods: Between August 2023 and July 2024, patients who were critically ill in the emergency intensive care unit of a tertiary hospital in Beijing who required nasoenteric tube placement were enrolled in this study. Gastric tube decompression was used to facilitate the tip positioning of nasoenteric tubes inserted blindly (without direct visualization), at the bedside.

View Article and Find Full Text PDF

A novel technique of blindly positioning bronchial blockers for one-lung ventilation: a prospective, randomized, crossover study.

J Cardiothorac Surg

January 2025

Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.

Background: Several methods for blindly positioning bronchial blockers (BBs) for one-lung ventilation (OLV) have been proposed. However, these methods do not reliably ensure accurate positioning and proper direction. Here, we developed a clinically applicable two-stage maneuver by modifying a previously reported one-stage maneuver for successful insertion of a BB at the appropriate depth and direction in patients requiring lung isolation where a flexible bronchoscope (FOB) is not applicable.

View Article and Find Full Text PDF

Neuraxial Anesthesia and Risk of Root Damage: A 3D Ex Vivo Study.

NeuroSci

December 2024

Laboratory of Surgical Neuroanatomy (LSNA), Human Anatomy and Embryology Unit, Faculty of Medicine and Health Sciences, Universitat de Barcelona, 08036 Barcelona, Spain.

Cauda equina nerve roots may become damaged during neuraxial anesthesia, and post-puncture headache may appear in the case of cerebrospinal fluid leakage if needle tips are deformed due to bone contact when several attempts are needed. Our aim was to verify the correlation between skin-transverse process distance (st) and skin-dural sac distance (d) for calculation of optimal angles in a free visual guide and as a reference for the maximal depth to be traversed by the needle. Randomly selected ex vivo samples ( = 10) were flexed to reproduce the position of the lumbosacral spine during spinal anesthesia.

View Article and Find Full Text PDF

Background: Multi-resistant Gram-negative bacteria (GNB) survive in hospital drains in traps that contain water and may ascend into the sink because of splashes, or biofilm growth.

Aim: To investigate whether the 'Tuba Drain' (TD) a long, bent, continually descending copper tube between the sink outlet and the trap prevents the ascent of bacteria.

Methods: After initial laboratory tests confirmed that the TD prevented bacteria in the U-bend from splashing upwards into the sink outlet, TDs were assessed in a randomized, blinded trial in a hospital outpatient department built in 2019.

View Article and Find Full Text PDF
Article Synopsis
  • The study compares two insertion methods for the LMA Blockbuster in children: blind insertion versus Miller laryngoscope-guided insertion, focusing on oropharyngeal leak pressure (OPLP) as the primary outcome.
  • Results showed that guided insertion had a significantly higher mean OPLP (27.9 cmHO) compared to blind insertion (25.94 cmHO), indicating better airway positioning.
  • While guided insertion took longer (11.9 seconds) than blind insertion (8.7 seconds), there were no significant differences in first-attempt success, haemodynamic stability, or postoperative complications.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!