Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This review describes the development of single-photon emission tomography (SPECT) in the Copenhagen area under the leadership of the internationally renown scientist, Niels A. Lassen, and the history leading up to construction of the tomograph. Measurements of global cerebral blood flow (CBF) in the 1940s and 1950s were performed by Kety & Schmidt and Lassen & Munck. Determination of regional cerebral blood flow (rCBF) by intra-arterial injection of Xe and measurement with a 254-multicrystal scintillation detector and a computer system was a major step forward in the study of physiology and pathophysiology of cortical cerebral blood flow. Tomography with radioisotope ligands, including non-invasive administration, was advanced in different centres during the 1970s. An emission tomograph, the Tomomatic 64, was developed as a result of a multidisciplinary Danish and international collaboration. It was the first emission tomograph to provide dynamic data that could produce cross-sectional rCBF images. The present description of the construction and function of the Tomomatic 64 includes comparison with other contemporary and later brain-dedicated SPECT systems. Basic and clinical application of the Tomomatic 64 in Copenhagen resulted in several hundred important scientific publications and improved diagnostics for patients with a variety of neurological disorders. It is concluded that the development of the Tomomatic 64 was a major step forward in the study and examination of rCBF and brain function related to several brain disorders, in addition to vascular diseases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/cpf.12663 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!