A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Non-invasive assessment of haemodynamic parameters in patients after Fontan procedure. | LitMetric

Non-invasive assessment of haemodynamic parameters in patients after Fontan procedure.

Ann Agric Environ Med

University Centre for Cardiology, Department of Family Medicine, Medical University, Gdansk, Poland.

Published: September 2020

Introduction And Objective: Single ventricle anomaly is one of the complex congenital heart defects. A dependable non-invasive method of evaluation of Fontan circulation haemodynamics for early diagnosing unstable patients is hardly available in routine clinical practice. The aim of the study is non-invasive evaluation of the haemodynamic parameters in patients after Fontan operation.

Material And Methods: The study involved 11 participants (age 24.4±4.3 years) with functionally univentricular hearts after Fontan operation. Evaluation of haemodynamic parameters was performed in supine and sitting positions using the impedance cardiography method.

Results: In comparative analysis, heart rate (70.1 vs.78.3 1/min; p=0.001), diastolic blood pressure (73.9 vs. 76.7 mm Hg; p=0.026), mean arterial blood pressure (84.5 vs. 88.0 mm Hg; p=0.013), systemic vascular resistance (1284.8 vs. 1334.9 dyn*s*cm-5; p=0.024), systemic vascular resistance index (2178.7 vs. 2272.8 dyn*s*cm-5*m2 ; p=0.018), pre-ejection period (124.2 vs. 136.2 ms; p=0.009), systolic time ratio (0.43 vs. 0.53; p=0.0001), and Zo (26.2 vs. 28.7 Ω; p<0.00001), were significantly higher in the sitting position. Stroke volume (75.4 vs. 68.5 ml; p=0.013), stroke index (42.7 vs. 39.0 ml*m-2; p=0.014), thoracic fluid content (38.5 vs. 35.4 1*kΩ-1; p=<0.00001), thoracic fluid content index (22.8 vs. 21.0 1*kΩ-1*m-2; p=<0.00001), and leftventricular ejection time 291.1 vs. 260.1 ms; p <0.00001, were significantly higher in the supine position.

Conclusions: In patients after Fontan procedure, impedance cardiography can be a useful tool the assessment of shortterm haemodynamic changes provoked by postural changes. Its clinical value in patients with congenital heart defects should be further investigated.

Download full-text PDF

Source
http://dx.doi.org/10.26444/aaem/109973DOI Listing

Publication Analysis

Top Keywords

haemodynamic parameters
12
parameters patients
8
patients fontan
8
evaluation haemodynamic
8
blood pressure
8
systemic vascular
8
vascular resistance
8
non-invasive assessment
4
assessment haemodynamic
4
fontan
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!