A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of hydroxylated phenylalkylamine stimulants in urine by GC-APPI-HRMS. | LitMetric

A gas chromatography-atmospheric pressure photoionization-high-resolution mass spectrometry (GC-APPI-HRMS) method was developed for the determination of eight phenylalkylamine stimulants in urine samples. Spiked urine samples were hydrolyzed, processed by solid-phase extraction, and derivatized before analysis. Two derivatization reactions were studied: the formation of trimethylsilyl (TMS) derivatives with N-methyl-N-trimethylsilyl trifluoroacetamide (MSTFA) and trimethylsilyl/trifluoroacetyl (TMS/TFA) derivatives with MSTFA and N-methyl-bis (trifluoroacetamide) (MBTFA) as derivatization reagents. Gas chromatography of both derivatives was performed with a 100% dimethylsiloxane column and a good separation of all isomeric compounds was achieved. To maximize the signal of the protonated molecule [M+H], the APPI most critical parameters were optimized. Three solvents were tested as dopant agents, with acetone yielding the lower in-source collision-induced dissociation (CID) fragmentation. The acquisition was performed in full scan and product ion scan (parallel reaction monitoring, PRM) using a quadrupole-Orbitrap mass analyzer (35,000 FWHM at m/z 200) in positive ion detection mode. At the optimal working conditions, the full scan method was evaluated for the fulfillment of identification requirements in doping analysis. Selectivity, limits of detection, matrix effect, and precision were estimated to validate the method for confirmation purposes and its applicability was tested by the analysis of spiked samples as well as by the analysis of samples obtained after the administration of some of the compounds to healthy volunteers. Results were compared with those obtained by GC-electron ionization-MS, demonstrating that the GC-APPI-HRMS method improved selectivity and sensibility, achieving lower limits of detection and satisfactory reproducibility.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-020-02913-0DOI Listing

Publication Analysis

Top Keywords

phenylalkylamine stimulants
8
stimulants urine
8
gc-appi-hrms method
8
urine samples
8
full scan
8
limits detection
8
analysis
5
analysis hydroxylated
4
hydroxylated phenylalkylamine
4
urine gc-appi-hrms
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!