Objective: This study aimed to determine the effect of macro design in the primary stability of short and extra-short implants using resonance frequency analysis (RFA).
Material And Methods: On an ex-vivo model using pig's ribs, we inserted 80 short and extra-short dental implants (20 implants per brand): Biohorizons®(B) 4.6 × 6mm; Intralock®(I) 4.75 × 6.5 mm; Straumann®(S) 4.1 × 4mm; and Tixos®(T) 5 × 5mm. Primary implant stability was measured using an RFA device. We compared mean ISQ values through ANOVA test.
Results: Mean ISQ values: B = 73.36 (±3.39); I = 75.13 (±3.88); S = 65.38 (±8.38); T = 72.13 (±11). B and I showed higher ISQ than S (p-value < 0.001). Short (I) showed higher ISQ than extra-short (B,S,T) implants (p-value = 0.001). Tapered (B,I) had higher ISQ than parallel (S,T) implants (p-value < 0.001). There was a moderate positive correlation between ISQ and length (r = 0.52), and a weak correlation with diameter (r = 0.33).
Discussion: The final result is a combination of implant design, length, and diameter. Tapered design (B and I) and larger implants (I) showed better primary stability in terms of ISQ values. This information could be beneficial at implant selection in a severely reabsorbed low-quality bone, privileging length (as long as it is safe), and conical walls design.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7486604 | PMC |
http://dx.doi.org/10.1016/j.jobcr.2020.08.020 | DOI Listing |
J Dent
November 2024
Department of Dentistry, Federal University of Santa Catarina (UFSC), Florianópolis, Brazil; College of Dentistry, University of Illinois Chicago (UIC), Chicago, USA.
J Funct Biomater
September 2024
Odontology at Ilapeo College, Curitiba 80710-150, Brazil.
This study aimed to assess clinical and radiographic outcomes, including implant survival, marginal bone loss, and patient satisfaction, in individuals with severe bone atrophy treated using a newly developed system of short and extra-short implants. A total of 44 implants (37 short and 7 extra-short) were placed with immediate loading in 11 patients. The patients were followed up at between 6 and 24 months.
View Article and Find Full Text PDFJ Intell
October 2024
Department of Psychology, Heidelberg University, Hauptstr. 47-51, 69117 Heidelberg, Germany.
Figural matrices tests are frequently used to measure fluid intelligence. The HeiQ-an operation-oriented figural matrices test-was developed to tackle limitations of previous matrices tests, mainly the possibility of excluding distractors based on superficial features instead of actively solving the items. However, allowing for a total administration time of 60 min for the assessment of one construct is not feasible in many study designs.
View Article and Find Full Text PDFDent J (Basel)
September 2024
University Institute for Regenerative Medicine and Oral Implantology-UIRMI (UPV/EHU-Fundación Eduardo Anitua), 01007 Vitoria, Spain.
This randomized controlled split-mouth trial compared the performance of 5.5 mm length implants (test group; TG) splinted within the same fixed prosthesis as longer implants (≥6.5 mm; control group; CG) in posterior regions.
View Article and Find Full Text PDFHealthcare (Basel)
August 2024
Department of Developmental and Social Psychology, Sapienza University of Rome, 00185 Rome, Italy.
(1) Background: Physical activity is known to promote health and psychological well-being in older adults, yet global inactivity rates in this population remain high. Among the factors associated with physical activity, self-efficacy for exercise represents a key predictor for developing effective interventions in older adults. This study aimed to validate the Self-Efficacy for Exercise Scale (SEE) in individuals over 65.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!