AI Article Synopsis

  • Posterior interosseous nerve (PIN) entrapment syndrome is a rare condition often caused by anatomical factors, with the Arcade of Frohse being the most common site of entrapment.
  • The study involved dissection of 100 upper limbs to map the entrance and exit points of the PIN in relation to the supinator muscle and measure specific distances from the radial head.
  • Results showed that the exit points of the PIN were predominantly muscular, indicating that about one-third of patients may experience additional entrapment at this site, which is important for surgical treatment considerations.

Article Abstract

Background: Posterior interosseous nerve (PIN) entrapment syndrome is a rare condition and is predisposed by anatomical factors such as narrow passages through fibrous arcades; whereas, the Arcade of Frohse (AF) is the most common entrapment point. The aim of this study was to evaluate the entrance and exit points of the PIN into the supinator in detail.

Materials And Methods: One hundred unpaired upper extremities underwent dissection. The PIN's entrance and exit points from the supinator were depicted. The distances between the tip of the radial head (RH) and the AF and the exit point of the PIN from the supinator were measured. Further, it was checked if the borders of the AF and the exit point were muscular, tendinous or a combination of these.

Results: The interval between the PIN's entry into the supinator and the tip of the RH was at a mean of 28.9 mm. Concerning the border of the AF, in 54 cases a muscular and in 46 specimens a tendinous version could be observed. The interval between the exit point of the PIN and the tip of the RH proved to be at a mean of 64.2 mm. Further, the exit's border was muscular in 65 specimens and tendinous in 35 cases.

Conclusion: During surgical treatment of the PIN syndrome, it needs to be kept in mind that approximately one-third of all patients might also suffer from entrapment at the exit point of the PIN.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7474043PMC
http://dx.doi.org/10.1007/s43465-020-00084-9DOI Listing

Publication Analysis

Top Keywords

exit point
16
point pin
12
posterior interosseous
8
interosseous nerve
8
entrapment syndrome
8
entrance exit
8
exit points
8
pin supinator
8
muscular specimens
8
specimens tendinous
8

Similar Publications

Based on the 5615 working face of Beisu Coal Mine, a virtual prototype of the shearer cable drag system was developed using the MG2×70/325-BWD electric traction shearer as the carrier, in combination with CERO and ADAMS software. The shearer cable was equivalently modeled using the discrete rigid body method to study the dynamic characteristics of the drag system. This research provides a foundation for the design and optimization of both the cable and cable clamps.

View Article and Find Full Text PDF

In this study we evaluated the effects of flow lamination on aerosol flow dynamics and deposition at the exit point in testing models with spatial barriers (narrowing or curving).We compared ModiFlow (MF) to an idealized Standard Spacer (SS) in their efficiency of delivery of aerosolized medication (fluticasone) across different types of spatial barriers. Fluticasone propionate HFA Inhaler from Prasco Labs 220 µg per actuation was used to deliver 1 spray in each test tube.

View Article and Find Full Text PDF

Burkholderia cenocepacia outbreak linked to taps in a neonatal intensive care unit.

Infect Dis Health

December 2024

Infection Prevention and Epidemiology, Monash Health, Clayton Australia; Monash University, Clayton, Australia; South East Public Health Unit, Monash Health, Clayton, Australia.

Background: Burkholderia cenocepacia complex is an important cause of hospital acquired infections. We describe the management of an outbreak in a neonatal intensive care unit (NICU) due to tap colonisation.

Methods: Microbiological testing of touch (n = 26) and non-touch taps (n = 28), sinks and drains, including genomic sequencing of selected isolates.

View Article and Find Full Text PDF

Closed globe refixation of the IOL-bag complex with the ab-externo 8-exit-4-point fixation technique.

Indian J Ophthalmol

December 2024

Department of Vitreo-Retina, Narayana Nethralaya, Bengaluru, Karnataka, India.

Intraocular lens (IOL) dislocation is not an uncommon complication and often requires surgical intervention, depending on the status of capsular bag support. Conventionally, posterior dislocation of a foldable IOL or the IOL-bag complex warrants their removal as foldable IOLs are not ideal for sulcus placement. The technique presented here describes using quadrilateral sutures to refix looped haptic IOLs at the ciliary sulcus with or without a bag complex.

View Article and Find Full Text PDF

The examination of wastewater and effluents flowing into receiving water bodies is crucial for identifying pollutant sources and implementing scenarios to reduce them. In this study, QUAL2kw was used to identify, assess, and predict the pollutant load of a drainage canal located 6 km away from Anzali Wetland. Initially, the model was calibrated and validated with data collected in 2017.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!