Rates of permanent pacemaker (PPM) implantation following transcatheter aortic valve implantation (TAVI) are higher than following surgery and are dependent on patient factors and valve type. There is an increasing trend towards pre-emptive PPM insertion in patients with significant conduction disease prior to TAVI. We report results from the British Cardiovascular Intervention Society (BCIS) on pre- and post-procedural PPM implantation in the TAVI population. All centres in the United Kingdom performing TAVI are required to submit data on all TAVI procedures to the National database which are then reported annually. During 2015, there were 2373 TAVI procedures in the UK. 22.4% of TAVI patients had a PPM implanted either pre-procedure (including the distant past), or during the in-hospital procedural episode. Of these, 7.9% were pre-procedure and 14.5% post-procedure. Overall PPM rates were Edwards Sapien (13.5%), Medtronic CoreValve (28.2%) and Boston Lotus (42.1%; p < 0.01). Pre-procedure pacing rates were Edwards Sapien (6.0%), Medtronic CoreValve (9.1%) and Boston Lotus (12.3%; p < 0.01). Pre-procedural pacing rates for the Boston Lotus valve have risen year-on-year from 5.8% (2013) to 8.6% (2014) to 12.3% (2015). The UK TAVI Registry demonstrates a pre-procedural permanent pacing bias amongst patients receiving transcatheter valves with higher post-procedure pacing rates. Pre-emptive permanent pacing is likely to be responsible for this difference.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00380-020-01703-zDOI Listing

Publication Analysis

Top Keywords

transcatheter aortic
8
tavi
8
ppm implantation
8
implantation tavi
8
tavi procedures
8
ppm
5
pre-procedural pacing
4
pacing bias
4
bias transcatheter
4
aortic valves
4

Similar Publications

Aims: Evidence regarding the safety of early discharge following transcatheter aortic valve implantation (TAVI) is limited. The aim of this study was to evaluate the safety of very early (<24) and early discharge (24-48 h) as compared to standard discharge (>48 h), supported by the implementation of a voice-based virtual assistant using artificial intelligence (AI) and natural language processing.

Methods And Results: Single-arm prospective observational study that included consecutive patients who underwent TAVI in a tertiary hospital in 2023 and were discharged under an AI follow-up programme.

View Article and Find Full Text PDF

Introduction: Pelvic fractures often result in life-threatening bleeding and hemodynamic instability. Resuscitative endovascular balloon occlusion of the aorta (REBOA) has emerged as a promising strategy for patients with severe pelvic fractures, facilitating subsequent hemostatic interventions. Transcatheter arterial embolization (TAE) is a well-established procedure for managing pelvic fractures accompanied by hemorrhage.

View Article and Find Full Text PDF

Higher and prohibitive mitral valve disease surgical scenarios are preferred cases for transcatheter mitral valve replacement as they offer unrelenting mitral valve regurgitation reduction. This review entails medical technologies that are evolving bioprosthetic devices for mitral valve repair and replacement purposes. Transcatheter mitral valve replacement is compared with transcatheter aortic valve implantation based on the etiology and driving factors.

View Article and Find Full Text PDF

Balloon-assisted percutaneous thrombin injection in a subclavian artery pseudoaneurysm: A case report.

Radiol Case Rep

March 2025

Department of Medical Imaging, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, Jeddah, Saudi Arabia.

Subclavian artery pseudoaneurysm (SAP) is a rare but lethal diagnosis, and an important condition that should be detected and managed imperatively. SAP has been seldom described in the literature, explaining the lack of concrete management guidelines. Herein we present a case study of a 63-year-old man with SAP post a transcatheter aortic valve implantation (TAVI) done 8 days prior to current presentation.

View Article and Find Full Text PDF

Background: Data supporting the use of transcatheter aortic valve replacement (TAVR) for bicuspid aortic valve (BAV) is limited compared to tricuspid aortic valve (TAV) anatomy, as the BAV anatomy poses unique challenges to prosthesis expansion and symmetric deployment.

Aims: We aim to compare the acute recoil and asymmetry of the SAPIEN-3 valve between BAV and TAV anatomies and their impact on procedural outcomes.

Methods: We conducted a single-center study of patients who underwent TAVR with the SAPIEN-3 valve.

View Article and Find Full Text PDF