A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel fluoroscopy-based robot system for pedicle screw fixation surgery. | LitMetric

Background: Robot-assisted pedicle screw insertion has gained popularity in the spinal surgery field. Due to high cost, these spinal robots are not extensively applied in clinical surgeries. Developing an effective robot system with low cost and high clinical acceptability is one of the future trends.

Methods: We developed a novel fluoroscopy-based robot system for pedicle screw insertion. Four live pigs were conducted with percutaneous pedicle screw insertion. Robot-assisted surgery was performed on the left side of pedicle, while the right opposite side is placed by freehand. The respect accuracy, surgical time and fluoroscopy time were recorded.

Results: Robot-assisted group achieved 100% (23/23) accuracy. The average times (6.4 ± 1.7) for intraoperative fluoroscopy usage per procedure were lesser than freehand group (12.5 ± 3.6), and the surgical time (6.8 ± 2.1 min) per screw was reduced compared with freehand group (12.1 ± 4.8 min).

Conclusions: Our robot system is cost-effective and feasible for pedicle screw placement. Low economic cost makes it easier for extensive application in primary hospitals.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcs.2171DOI Listing

Publication Analysis

Top Keywords

pedicle screw
20
robot system
16
screw insertion
12
novel fluoroscopy-based
8
fluoroscopy-based robot
8
system pedicle
8
surgical time
8
freehand group
8
pedicle
6
screw
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!