Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: Reintubation after failed extubation is associated with increased mortality and longer hospital length of stay. Noninvasive oxygenation modalities may prevent reintubation. We conducted a systematic review and meta-analysis to determine the safety and efficacy of high-flow nasal cannula after extubation in critically ill adults.
Data Sources: We searched MEDLINE, EMBASE, and Web of Science.
Study Selection: We included randomized controlled trials comparing high-flow nasal cannula to other noninvasive methods of oxygen delivery after extubation in critically ill adults.
Data Extraction: We included the following outcomes: reintubation, postextubation respiratory failure, mortality, use of noninvasive ventilation, ICU and hospital length of stay, complications, and comfort.
Data Synthesis: We included eight randomized controlled trials (n = 1,594 patients). Compared with conventional oxygen therapy, high-flow nasal cannula decreased reintubation (relative risk, 0.46; 95% CI, 0.30-0.70; moderate certainty) and postextubation respiratory failure (relative risk, 0.52; 95% CI, 0.30-0.91; very low certainty), but had no effect on mortality (relative risk, 0.93; 95% CI, 0.57-1.52; moderate certainty), or ICU length of stay (mean difference, 0.05 d fewer; 95% CI, 0.83 d fewer to 0.73 d more; high certainty). High-flow nasal cannula may decrease use of noninvasive ventilation (relative risk, 0.64; 95% CI, 0.34-1.22; moderate certainty) and hospital length of stay (mean difference, 0.98 d fewer; 95% CI, 2.16 d fewer to 0.21 d more; moderate certainty) compared with conventional oxygen therapy, however, certainty was limited by imprecision. Compared with noninvasive ventilation, high-flow nasal cannula had no effect on reintubation (relative risk, 1.16; 95% CI, 0.86-1.57; low certainty), mortality (relative risk, 1.12; 95% CI, 0.82-1.53; moderate certainty), or postextubation respiratory failure (relative risk, 0.82; 95% CI, 0.48-1.41; very low certainty). High-flow nasal cannula may reduce ICU length of stay (moderate certainty) and hospital length of stay (moderate certainty) compared with noninvasive ventilation.
Conclusions: High-flow nasal cannula reduces reintubation compared with conventional oxygen therapy, but not compared with noninvasive ventilation after extubation.