Robotic-Assisted Pedicle Screw Placement During Spine Surgery.

JBJS Essent Surg Tech

Scoliosis and Spine Tumor Center, Texas Back Institute, Plano, Texas.

Published: May 2020

Unlabelled: Preoperative planning software and a robotic device facilitate the placement of pedicle screws, especially in patients with difficult anatomy, thereby increasing the feasibility, accuracy, and efficiency of the procedure. The robot functions as a semiactive surgical assistive device whose goal is not to substitute but to offer the surgeon a set of versatile tools that can broaden his or her ability to treat patients.

Description: The robotic guidance system consists of a bed-mounted surgical arm and a workstation. We used the Mazor X Stealth Edition Robotic Guidance System by Medtronic for spine surgery, which has been previously described. Unlike other systems that are navigation-based and require an optical tracking mechanism, this system relies on the preoperative plan to be referenced using the intraoperative registration. The workstation runs an interface software that facilitates preoperative planning, intraoperative image acquisition and registration, kinematic calculations, and real-time robot motion control. The robotic arm is mounted onto the bed as well as rigidly attached to the patient's spine. It can move in 6 degrees of freedom to provide the preplanned screw trajectory and entry point thereby allowing the surgeon to manually perform the drilling and screw insertion through either an open or percutaneous procedure by first seating a drill tube and then drilling and tapping the hole as needed.

Alternatives: Other robotic systems include the ROSA robot by Medtech, the ExcelsiusGPS robot by Globus Medical, and the SurgiBot and ALF-X Surgical Robotic systems (both from TransEnterix). The Da Vinci Surgical System (Intuitive Surgical) has been utilized for laparoscopic anterior lumbar interbody fusion (ALIF), but it has not been approved by the U.S. Food and Drug Administration for actual spinal instrumentation. Alternative surgical techniques for pedicle screw placement include the freehand fluoroscopy-guided technique and intraoperative image-assisted computer navigation techniques, including isocentric C-arm (Iso-C) 3D (3-dimensional) navigation (Siemens), computed tomography (CT) navigation, O-arm navigation (Medtronic), CT-magnetic resonance imaging co-registration technology, and a 3D-visual guidance technique.

Rationale: The robotic-guided pedicle screw placement offers the following benefits over conventional dorsal instrumentation techniques: improved accuracy and safety in pedicle screw insertion; precision in screw size selection and planned screw positioning; a reduction in exposure to radiation for the surgeon, the patient, and the operating-room staff; simplicity and user-friendliness with a moderate learning curve; ease of registration and reduction of operating time; significant enhancement of the surgeon's ergonomics and dexterity for repetitive tasks in pedicle screw placement; and a wider coverage in function to include utilization during minimally invasive surgery where applicable.

Expected Outcomes: Accuracy rates between 94.5% and 99%, comparable with those in our study, have been reported with the robotic-guided pedicle screw insertion technique, even in studies involving complex deformities and revision surgeries for congenital malformations, degenerative disorders, destructive tumors, and trauma. The safety of this technique, in terms of reduced complications and intraoperative radiation exposure, has also been documented as higher than that for freehand fluoroscopic guidance or other navigation techniques. The feasibility of this procedure has been further extended to minimally invasive procedures and to use in the cervical region, with replication of its advantages. It is associated with a reasonable learning curve, with consistent successful results after 25 to 30 patients.

Important Tips: The principles of robotic-guided pedicle screw placement are similar irrespective of the system used.Although initially utilized mainly for thoracolumbar pedicle screw insertion, the latest robots and software have been adapted for use in the cervical spine with equivalent efficiency and accuracy.Robotic guidance can be employed in non-pedicle-screw-insertion procedures.Challenges include radiation exposure, trajectory failure, equipment and software failure, failed registration, logistics, time, and high cost.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7478327PMC
http://dx.doi.org/10.2106/JBJS.ST.19.00020DOI Listing

Publication Analysis

Top Keywords

pedicle screw
32
screw placement
20
screw insertion
16
screw
12
robotic-guided pedicle
12
spine surgery
8
preoperative planning
8
pedicle
8
robotic guidance
8
guidance system
8

Similar Publications

Osteoporotic vertebral fractures (OVFs) in elderly patients pose challenges due to bone destruction and surgical risks. This case report describes a minimally invasive approach using calcium phosphate cement (CPC) vertebroplasty and short fusion with cement augmentation of pedicle screws (CAPS) in a 91-year-old woman with severe OVF. The patient underwent CPC vertebroplasty at L1 and CAPS fixation at T12-L2, followed by osteoporosis medication.

View Article and Find Full Text PDF

Rationale: Alkaptonuria (AKU) is a rare, inherited metabolic disease caused by deficient activity of homogentisic acid oxidase, leading to the accumulation of homogentisic acid and its oxidized product, benzoquinone acetic acid. These compounds cause black discoloration of cartilage, degeneration, inflammation, and calcification of intervertebral disks and large joints, resulting in pain and impaired quality of life. Despite its debilitating effects, there are no curative treatments for AKU, and management remains supportive.

View Article and Find Full Text PDF

Study Design: Retrospective Cohort Study.

Objective: This study aimed to compare outcomes in AIS patients that underwent PSF using either freehand with occasional fluoroscopic assistance (FOFA), computer assisted surgery/navigation (CAS), or technique and technology (T&T).

Summary Of Background Data: Pedicle screw insertion in scoliosis is challenging due to abnormal pedicle morphology.

View Article and Find Full Text PDF

Background: This meta-analysis was conducted to compare the efficacy and safety of vertebral augmentation (VA) plus pedicle screw fixation (PSF) with VA for treating osteoporotic thoracolumbar fractures (OTLFs).

Methods: A comprehensive search was conducted in PubMed, Embase, Cochrane Library and China National Knowledge Infrastructure (CNKI) to identify studies comparing PSF+VA with VA for treating OTLF. The primary outcomes were operation time, blood loss, length of stay, visual analogue scale (VAS) score, Oswestry disability index (ODI), Cobb angle, anterior vertebral height (AVH), bone cement leakage, secondary fracture and other adverse events.

View Article and Find Full Text PDF

Background: In atlantoaxial instabilities, posterior C1/C2 fusion using lateral mass screws (LMS) or pedicle screws (PS) in a mono- or bicortical position in the atlas is a typical treatment. The bone microstructure and positioning of the screw trajectories appear to be of significant relevance for stability.

Purpose: The aim of this study was a comparative analysis of the mechanical durability of screw fixation concerning microstructural characteristics of the trajectories of LMS and PS in mono- and bicortical position.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!