A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Randomized Trial of 2 Self-Titrated Oral Appliances for Airway Management. | LitMetric

The effectiveness and predictability of 2 different oral appliance (OA) designs to reduce the respiratory event index (REI) in moderate and severe obstructive sleep apnea (OSA) patients requires elucidation. The primary aim of the trial was to determine if 2 widely used midline-traction and bilateral-thrust OA designs differ in effectiveness to reduce the REI within a single test population categorized by OSA severity. Moderate and severe adult OSA patients, who were previously prescribed continuous positive airway pressure therapy (CPAP) but were dissatisfied with it ( = 56), were studied by home-polygraphy in a randomized crossover trial using either midline-traction with restricted mouth opening (MR) or bilateral thrust with opening permitted (BP) design OAs. OAs were used nightly for 4 wk (T2) followed by a 1-wk washout period, then 4 wk (T4) using the alternate OA. REI and oxygen saturation (SaO) were primary outcomes, while predictability and efficacy comparison of the 2 OAs were secondary outcomes. Thirty-six participants had used MR and BP OAs during both 4-wk study legs. Twenty (55.6%) MR OA-using participants, 25 (69.4%) BP OA-using participants, and 16 (44.4%) participants using both OAs had significant REI reductions. Overall baseline (T0) median REI (interquartile range) of 33.7 (20.7-54.9) was reduced to 18.0 (8.5-19.4) at T2 and to 12.5 (8.2-15.9) at T4 ( < 0.001). Comparison of the 2 sequence groups' (MR-BP and BP-MR) REI showed the median differences between T0 and T2 and T4 were highly significant ( < 0.001). Regression analysis predicted about half of all users will have REIs between 8 and 16 after 2 mo. Baseline overjet measures >2.9 mm predicted greater OA advancement at T4. Mean and minimum SaO did not change significantly from T0 to T2 or T4. MR and BP OA designs similarly attenuated REI in moderate and severe OSA individuals who completed the 8-wk study protocol with greater REI reduction in those with severe OSA (ClinicalTrials.gov NCT03219034).

Download full-text PDF

Source
http://dx.doi.org/10.1177/0022034520956977DOI Listing

Publication Analysis

Top Keywords

moderate severe
12
rei
8
rei moderate
8
osa patients
8
participants oas
8
oa-using participants
8
severe osa
8
osa
5
oas
5
randomized trial
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!