A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance analysis of a hybrid ventilation system in a near zero energy building. | LitMetric

In this research paper, an analysis is developed on the performance of a hybrid ventilation system that combines Earth-to-Air Heat eXchangers (EAHX), free cooling and evaporative cooling Air Handling Unit Heat eXchanger (AHU-HX), all being controlled by a Building Management System (BMS) in a net Zero Energy Building (nZEB), called LUCIA. LUCIA nZEB is the first safe-building against Covid-19 in the world, certified by the international organisation WOSHIE, and located in Valladolid, Spain. The main aim is to optimize the performance of the three systems in such a way that the Indoor Air Quality (IAQ) levels remain within the allowable limits, while maximizing the use of natural resources and minimizing energy consumption and carbon emissions. The approach to satisfy the heating and cooling demand and IAQ levels through zero emissions energy systems is developed, thus anticipating the zero-energy target, set by the European Union for 2050. Results showed that the installed hybrid ventilation system uses heat exchangers for 70% of the operational time, in order to achieve the set parameters successfully. Also, the analysis made by monitoring data, have shown that the control and optimal operation of the hybrid ventilation system allows high energy recovery values with minimum additional electricity consumption. Significant reduction of carbon emissions and operational costs have been achieved.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7482603PMC
http://dx.doi.org/10.1016/j.buildenv.2020.107265DOI Listing

Publication Analysis

Top Keywords

hybrid ventilation
16
ventilation system
16
energy building
8
heat exchangers
8
iaq levels
8
carbon emissions
8
system
5
energy
5
performance analysis
4
hybrid
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!