A stripping voltammetric assay using a morin modified electrode in a sequential injection lab-on-valve system was developed for the determination of trace amounts of cadmium. The sample and reagent arrangements were achieved by a syringe pump. The target metal ions were accumulated on the morin modified glassy carbon electrode surface, and the quantification step was performed by subsequent anodic stripping voltammetry. The key experimental variables relevant to the voltammetric measurement procedure were optimized. For a 100 s preconcentration time, a linear calibration curve was obtained for a concentration range of 1 to 125 μg L-1 with a detection limit of 0.41 μg L-1. The analytical use of the established method was assessed by applying it to the determination of cadmium in real samples and carrying out recovery experiments. The method was subsequently validated by comparing the results with those given by ICP-OES.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c0ay00664eDOI Listing

Publication Analysis

Top Keywords

sequential injection
8
injection lab-on-valve
8
lab-on-valve system
8
modified electrode
8
morin modified
8
μg l-1
8
determination sequential
4
system voltammetric
4
voltammetric detection
4
detection modified
4

Similar Publications

Background: The increased apoptosis of bile duct epithelial cells (BECs) due to some damage factors is considered the initiating factor in the occurrence and progression of biliary atresia (BA). Vitamin D receptor (VDR) is thought to play a crucial role in maintaining the intrinsic immune balance and integrity of bile duct epithelial cells (BECs). To investigate the role of VDRs in the pathogenesis and progression of BA using in vitro and in vivo models.

View Article and Find Full Text PDF

Introduction: In facial cosmetic surgery, injectable liquid silicone has been used to augment the cheek and the lips and to camouflage facial wrinkles. However, complications started to arise in 1964 as postoperative silicone granuloma formation. The purpose of this study is to introduce our experience in facial reconstruction after injectable silicon oil with a sequential 3-step approach: transoral surgical excision, full-face fat grafting, and hyaluronic acid filler.

View Article and Find Full Text PDF

Purpose: The study aimed to evaluate the long-term efficacy and safety of superior laryngeal nerve (SLN) block for treating chronic neurogenic cough (CNC) in a large patient cohort.

Methods: A retrospective review was conducted on patients treated between January 2019 and October 2023. Data collected included patient demographics, number of injections, follow-up times, subjective cough severity, and Leicester Cough Questionnaire (LCQ) scores.

View Article and Find Full Text PDF

Introduction: Hyperthermia is an established adjunct in multimodal cancer treatments, with mechanisms including cell death, immune modulation, and vascular changes. Traditional hyperthermia applications are resource-intensive and often associated with patient morbidity, limiting their clinical accessibility. Gold nanorods (GNRs) offer a precise, minimally invasive alternative by leveraging near-infrared (NIR) light to deliver targeted hyperthermia therapy (THT).

View Article and Find Full Text PDF

Hyaluronic acid fillers rarely cause potentially devastating occlusive adverse events that require immediate hyaluronidase salvage infiltrations. An exploratory photographic investigation probed whether topical heparin's anticlotting and anti-inflammatory properties could synergize with and enhance the effectiveness of hyaluronidase. Based on heparin pharmacodynamics, the authors explored the rationale for associating topical heparins with hyaluronidase in treating occlusive side effects following accidental intra-arterial hyaluronic acid injections.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!