A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biotin immunoassay interference: A UK-based prevalence study. | LitMetric

Biotin immunoassay interference: A UK-based prevalence study.

Ann Clin Biochem

Black Country Pathology Services, The Dudley Group NHS Foundation Trust, Russells Hall Hospital, Dudley, UK.

Published: January 2021

Background: Biotin interference in biotin-streptavidin-based immunoassays is increasingly reported due to individuals taking biotin-containing supplements and patients prescribed biotin. The reported prevalence of serum biotin above the lowest threshold (≥10 g/L) for interference in Roche Diagnostics immunoassay tests is 0.8% in Australia and 7.4% in the USA. There are, however, no such data in UK populations. In a service evaluation, we therefore studied the prevalence of biotin interference in routine serum samples received in our laboratory.

Methods: Biotin was measured in 524 anonymized surplus serum samples in which at least one immunoassay test had been requested.

Results: The median (95% confidence intervals) for serum biotin was 0.27 g/L (0.07-0.93 g/L). Serum biotin was <10 g/L in all samples, <5 g/L in 522 (99.6%) and <1 g/L in 513 (98.1%) samples. In four samples, serum biotin was ≥2.5 g/L (0.8%).

Conclusions: These data indicate that the probability of biotin immunoassay interference in our patient population is extremely low, with the exception of assays reporting the lowest interference thresholds (e.g. Ortho Troponin I assay [threshold ≥2.5 g/L]).

Download full-text PDF

Source
http://dx.doi.org/10.1177/0004563220961759DOI Listing

Publication Analysis

Top Keywords

serum biotin
12
biotin
8
biotin interference
8
serum samples
8
serum
5
biotin immunoassay
4
interference
4
immunoassay interference
4
interference uk-based
4
uk-based prevalence
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!