A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In vivo biological safety evaluation of an iron-based bioresorbable drug-eluting stent. | LitMetric

Bioresorbable stents (BRS) are investigated and designed to revascularize occluded arteries. The iron-based bioresorbable stent is a promising device in interventional therapies, although it's corrosion and bioresorption rate remain challenging. In this work, we introduced a novel nitrided iron coronary stent (IBS) with enhanced degradation rate compared with pure iron stent. To evaluate the biosafety of this device, a sub-chronic systemic toxicity study was conducted and a stainless steel stent (Supporterâ„¢) served as a control. Here, the bioresorbable stent was first evaluated in rat abdominal aortic implantation model. When subjected to exaggerated exposure dose, no clinical signs of toxicity or mortality were observed in either, the IBS group or the control group. Histopathological examinations showed the corrosion particles of iron were encapsulated by fibrocytes and engulfed by macrophages, indicating that the degradation of iron was in the early stage. Our results demonstrated that the nitrided iron stent did not induce systemic toxicity under the experimental conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10534-020-00244-2DOI Listing

Publication Analysis

Top Keywords

iron-based bioresorbable
8
bioresorbable stent
8
nitrided iron
8
iron stent
8
systemic toxicity
8
stent
7
iron
5
vivo biological
4
biological safety
4
safety evaluation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!