The spread of infectious diseases among aquaculture species has a serious impact on the aquaculture industry. Simple, specific and low-cost detection methods are urgently needed for early diagnosis and timely treatment, particularly for on-site identifying and tracking of pathogens. Vibrio splendidus (V. splendidus) is regarded as one of the main pathogenic bacteria causing skin ulcerative syndrome in cultured sea cucumbers, leading to massive mortality and severe economic losses. We herein present a microfluidic-based real-time fluorogenic loop-mediated isothermal amplification (LAMP) system for simple and reliable detection of V. splendidus. A LAMP primer set with six primers (arsB1) specifically targeting the arsB gene of V. splendidus was successfully designed and tested on the portable microfluidic system for the first time. Only a single step of sample loading using a pipette is required to fill an array of reaction wells (with 10 or 18 wells) in a disposable chip for multiplex detection. A dedicated plastic shell is then utilized to tightly seal the openings of the chip by buckling to prevent contamination and evaporation. Up to four chips (one sample per chip) can be held in the stand-alone and inexpensive microdevice simultaneously, enabling on-demand detection of multiple samples in a single run. Reproducible (relatively low intra- and inter-chip variability) and sensitive (as few as ∼20 CFU, Colony-Forming Units, per reaction well) on-chip arsB1-LAMP assay was demonstrated by using diluted lysate of V. splendidus. A linear standard curve (R2 > 0.98) was attained over the template concentration range of 5 × 103 to 5 × 106 CFU mL-1. V. splendidus can be detected in samples containing different bacteria, indicating the feasibility of the portable microfluidic LAMP system for parallel detection of multiple bacterial pathogens. The proposed on-chip LAMP assay is simple to operate, reliable for amplification, flexible in detection and cost-effective in instrumentation and testing, holding great potential for on-site rapid detection and routine monitoring of aquaculture pathogens.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/d0ay00566e | DOI Listing |
Mikrochim Acta
January 2025
Department of Biotechnology and Bioengineering, Chonnam National University, Gwangju, 61186, Republic of Korea.
The global healthcare market increasingly demands affordable molecular diagnostics for field testing. To address this need, we introduce a lab-on-paper (LOP) platform that integrates isothermal amplification with a specially designed paper strip for molecular testing through an automated microfluidics process. The LOP system is engineered for rapid, cost-effective, and highly sensitive detection, using USB-powered thermal management and a wax valve mechanism.
View Article and Find Full Text PDFMicrosyst Nanoeng
January 2025
Department of Chemical and Biomolecular Engineering, Chonnam National University, 50 Daehak-ro, Yeosu-si, Jeollanam-do, 59626, Republic of Korea.
Developing a portable yet affordable method for the discrimination of chemical substances with good sensitivity and selectivity is essential for on-site visual detection of unknown substances. Herein, we propose an optofluidic paper-based analytical device (PAD) that consists of a macromolecule-driven flow (MDF) gate and photonic crystal (PhC) coding units, enabling portable and scalable detection and discrimination of various organic chemical, mimicking the olfactory system. The MDF gate is designed for precise flow control of liquid analytes, which depends on intermolecular interactions between the polymer at the MDF gate and the liquid analytes.
View Article and Find Full Text PDFAnal Chem
January 2025
State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Hunan University, Changsha 410082, China.
To facilitate on-site detection by nonspecialists, there is a demand for the development of portable "sample-to-answer" devices capable of executing all procedures in an automated or easy-to-operate manner. Here, we developed an automated detection device that integrated a magnetofluidic manipulation system and a signal acquisition system. Both systems were controllable via a smartphone.
View Article and Find Full Text PDFJ Agric Food Chem
January 2025
College of Ocean Food and Biological Engineering, Jimei University, Xiamen 361021, China.
In this study, we present an intelligent electromagnetic-actuated microfluidic chip integrated with a G-quadruplex DNAzyme-based biocatalysis platform for rapid and sensitive tetracycline (TC) detection. In this sensing system, TC significantly quenches fluorescent magnetic carbon dots (M-CDs) via the internal filtration effect and dynamic quenching (the excitation and emission wavelength at 350 and 440 nm, respectively). Then, the G-quadruplex on the M-CDs-Aptamer is exposed and bound with hemin to form hemin-G-quadruplex DNAzyme, catalyzing the conversion of 3,3',5,5'-tetramethylbenzidine to produce blue color.
View Article and Find Full Text PDFAnal Chim Acta
February 2025
Department of Hygiene, Third Faculty of Medicine, Charles University, Ruská 87, 100 00, Prague 10, Czech Republic. Electronic address:
The review focuses on the design of detection cells, the use of microcontrollers for processing and evaluation of the detection signal, and the development of multi-detection systems for electromigration, liquid chromatography, flow-through and microfluidic techniques. A separate section is the introduction of modern 3D printing techniques and the use of new printing materials for the design of multidetection systems. In addition to traditional utilisation in separation techniques, new versions of contactless conductivity detectors are finding applications in FIA, SIA, portable and paper based analytical systems or as independent sensors.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!