A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a HILIC-MS/MS method for the quantification of histamine and its main metabolites in human urine samples. | LitMetric

Development of a HILIC-MS/MS method for the quantification of histamine and its main metabolites in human urine samples.

Talanta

KU Leuven, Laboratory for Pharmaceutical Analysis, Herestraat 49, 3000, Leuven, Belgium. Electronic address:

Published: December 2020

An LC-MS/MS method was developed enabling the separation and quantification of histamine and its main metabolites (imidazole acetaldehyde, imidazole acetic acid, methyl imidazole acetic acid, methyl histamine, acetyl histamine) in urine samples. A fast separation was achieved in 10 min on two HILIC columns connected in series by adopting a linear gradient followed by an isocratic hold. The sample preparation consisted of a simple dilution step wherein 10 μL of urine was diluted with acetonitrile (ACN) to a final volume comprising 95% ACN. For methyl imidazole acetic acid, an additional dilution step was incorporated due to its high natural levels. Hereafter, the samples were stored at -20 °C and centrifuged prior to injection. Matrix matched calibrators were unavailable due to the endogenous occurrence of the compounds of interest. The occurrence of matrix effects and the lack of labeled internal standards prompted the use of the standard addition method as a viable alternative to solvent calibration. The validation of the method entailed matrix effects, accuracy and precision and was performed in compliance with the recent guidelines on endogenous compounds issued by the International Conference of Harmonization (ICH). The method was then adopted for the quantification of histamine and its metabolites in human urine samples collected from healthy volunteers and patients suffering from gastrointestinal discomfort.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2020.121328DOI Listing

Publication Analysis

Top Keywords

quantification histamine
12
urine samples
12
imidazole acetic
12
acetic acid
12
histamine main
8
main metabolites
8
metabolites human
8
human urine
8
acid methyl
8
methyl imidazole
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!