Objectives: To compare safety, efficacy, and hemodynamics of transfemoral transcatheter aortic valve replacement (TAVR) using self-expanding and balloon-expandable transcatheter heart valves (THVs) in patients with a small aortic annulus.

Background: Few studies have directly compared TAVR outcomes using third-generation THVs, focusing on patients with small aortic annuli.

Methods: In a multicenter TAVR registry, we analyzed data from 576 patients with a small annulus and who underwent transfemoral TAVR using third-generation THVs. Propensity score matching was used to adjust baseline clinical characteristics.

Results: The device success rate in the overall cohort was 92.0% (Evolut R: 92.1% vs. Sapien 3:92.0%, p = 0.96). One year after TAVR, patients treated with Evolut R maintained a lower mean pressure gradient (mPG) and a higher indexed effective orifice area (iEOA) in the matched cohort {mPG: 9.0 [interquartile range (IQR): 6.0-11.9] vs. 12.0 [IQR: 9.9-16.3] mmHg, p < .001; iEOA: 1.20 [IQR: 1.01-1.46] vs. 1.08 [IQR: 0.90-1.28] cm /m , p < .001}. However, no significant differences were reported in the incidence of severe prosthesis-patient mismatch and aortic regurgitation at 1 year. Furthermore, both groups showed comparable outcomes with no differences in terms of all-cause mortality (log-lank test, p = .81).

Conclusions: TAVR for patients with a small annulus using third-generation THVs was associated with high device success. Evolut R seems to be superior to Sapien 3 in hemodynamic performance for patients with a small annulus and body surface area up to 1 year after TAVR. Nevertheless, all-cause mortality at 1 year was similar between both groups.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.29259DOI Listing

Publication Analysis

Top Keywords

patients small
16
small aortic
12
transcatheter aortic
8
aortic valve
8
valve replacement
8
third-generation thvs
8
patients
5
tavr
5
replacement evolut
4
evolut versus
4

Similar Publications

sp. nov., isolated from a patient with ruptured appendicitis.

Int J Syst Evol Microbiol

January 2025

Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong Special Administrative Region, Hong Kong, PR China.

A clinical isolate, R131, was isolated from the peritoneal swab of a patient who suffered from ruptured appendicitis with abscess and gangrene in Hong Kong in 2018. Cells are facultatively anaerobic, non-motile, Gram-positive coccobacilli. Colonies were small, grey, semi-translucent, low convex and alpha-haemolytic.

View Article and Find Full Text PDF

Importance: Rotator cuff tendinopathy represents the most prevalent cause of shoulder pain, the third most common musculoskeletal disorder after low back pain and knee pain.

Objective: The objective of this study was to determine the effectiveness of corticosteroid injection(s), alone or in combination with anesthetic injection or any other physical therapist interventions, compared to physical therapist interventions alone in adults with rotator cuff tendinopathy.

Design: This study was a systematic review and meta-analysis of randomized controlled trials.

View Article and Find Full Text PDF

Purpose: Therapeutic efficacy of KRASG12C(OFF) inhibitors (KRASG12Ci) in KRASG12C-mutant non-small cell lung cancer (NSCLC) varies widely. The activation status of RAS signaling in tumors with KRASG12C mutation remains unclear, as its ability to cycle between the active GTP-bound and inactive GDP-bound states may influence downstream pathway activation and therapeutic responses. We hypothesized that the interaction between RAS and its downstream effector RAF in tumors may serve as indicators of RAS activity, rendering NSCLC tumors with a high degree of RAS engagement and downstream effects more responsive to KRASG12Ci compared to tumors with lower RAS---RAF interaction.

View Article and Find Full Text PDF

Background: Views surrounding acromioplasty at the time of arthroscopic rotator cuff repair (RCR) have shifted dramatically over time. In recent years, various studies have argued against acromioplasty, citing equivocal functional outcomes after arthroscopic RCR with or without acromioplasty.

Purpose: To assess the statistical fragility of functional outcomes after arthroscopic RCR with and without acromioplasty using the reverse continuous fragility index (RCFI).

View Article and Find Full Text PDF

Aneurysmal rupture in microscopic polyangiitis: a case-based review.

Clin Rheumatol

January 2025

Department of Medical Laboratory Science, Faculty of Health Sciences, Hokkaido University, Sapporo, Hokkaido, Japan.

Microscopic polyangiitis (MPA) affects small and medium vessel, which sometimes leads to arterial aneurysms. In English database, only 15 reports refer to ruptured aneurysms in MPA. We experienced a fatal case with MPA who developed multiple visceral aneurysms, resulting in rupture of the hepatic aneurysm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!