Study Design: Retrospective review.
Objective: The aim of this study was to evaluate the feasibility, safety,s and complications of computer tomography (CT) fluoroscopy-guided percutaneous transpedicular gold fiducial marker insertion to reduce incidence of wrong-level surgery in the thoracic spine.
Summary Of Background Data: Intraoperative localization of the correct thoracic level can be challenging and time-consuming, especially in obese patients and patients with anatomical variations. In the literature there are very few studies containing low numbers of patients which assessed CT or CT fluoroscopy-guided fiducial marker placement of the thoracic spine. Description of this technique has been similarly scarce.
Methods: All patients who underwent percutaneous CT fluoroscopy-guided gold fiducial marker placement of the thoracic spine were retrospectively reviewed. Indications for surgery included degenerative disc disease, infection, spinal metastasis, and intra- and extradural tumors. Gold fiducial markers were placed using a percutaneous CT fluoroscopy-guided transpedicular approach with local anesthesia. In addition, sex, age, body mass index (BMI), thoracic level, related pathology, and procedure-related complications were also recorded.
Results: A total of 57 patients (24 females, 33 males) were included. Mean age was 58.6 ± 15.5 years. No complications during CT fluoroscopy-guided gold fiducial marker placement were recorded. Intraoperative localization was successful in all patients. Mean BMI was 32.98 kg/m (range, 18.63-56.03 kg/m), and 63% of patients were obese (>30 kg/m). T7 (n = 11) was the most often marked vertebral body, followed by T10 (n = 10) and T6 (n = 7). The most cranial and most caudal levels marked were T2 and T12, respectively.
Conclusion: Preoperative CT fluoroscopy-guided percutaneous gold fiducial marker placement is safe, feasible, and accurate. The resulting facilitated localization of the intended thoracic level of surgery can reduce the length of surgery and prevent wrong-level surgery. Further studies are needed to evaluate in the effect on exposure to radiation and quantify the difference in operating room time.
Level Of Evidence: 4.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BRS.0000000000003691 | DOI Listing |
J Clin Med
September 2024
Department of Neurosurgery, Kantonspital Aarau, 5001 Aarau, Switzerland.
The accurate identification of intraoperative levels is of paramount importance in spinal surgery, particularly in cases of obesity or anatomical anomalies affecting the thoracic spine. The aim of this work was to clarify whether the preoperative percutaneous placement of fiducial markers under local anesthesia only, with minimal discomfort to the patient, can be performed safely and efficiently. Patients treated at our institution between June 2019 and June 2020 for thoracic intraspinal lesions with preoperative percutaneous gold fiducial placement were analyzed.
View Article and Find Full Text PDFMed Phys
November 2024
The D-Lab, Department of Precision Medicine, GROW School for Oncology and Reproduction, Maastricht University, Maastricht, The Netherlands.
Background: Stereotactic body radiation therapy for hepatocellular carcinoma necessitates the implantation of gold fiducial markers in the liver, resulting in artifacts on computed tomography (CT) scans, which affect radiomic feature values.
Purpose: This report aims to assess the effect of these artifacts on radiomic features and how removing CT slices affects radiomic features extracted from 3D regions of interest (ROI).
Methods: First, the range variation in 38 tumor contours unaffected by artifacts was assessed after sequentially and randomly removing 25%, 50%, 75% of slices.
Int J Mol Sci
July 2024
Department of Biological Engineering, University of California Santa Barbara, Santa Barbara, CA 93106, USA.
Gold nanoparticles with sizes in the range of 5-15 nm are a standard method of providing fiducial markers to assist with alignment during reconstruction in cryogenic electron tomography. However, due to their high electron density and resulting contrast when compared to standard cellular or biological samples, they introduce artifacts such as streaking in the reconstructed tomograms. Here, we demonstrate a tool that automatically detects these nanoparticles and suppresses them by replacing them with a local background as a post-processing step, providing a cleaner tomogram without removing any sample relevant information or introducing new artifacts or edge effects from uniform density replacements.
View Article and Find Full Text PDFFront Oncol
June 2024
Department of Radiation Oncology, Davidoff Cancer Center, Rabin Medical Center, Petah Tikvah, Israel.
Introduction: Precise patient positioning with image guidance (IGRT) is essential for safe prostate radiotherapy. We present the first report of utilizing a CT-visible hydrogel spacer, used to decrease rectal radiation dose, as a surrogate fiducial marker to aid in daily IGRT with cone-beam CT (CBCT) in stereotactic radiotherapy (SABR) for prostate cancer.
Materials And Methods: Prior to CT simulation, patients underwent placement of three intraprostatic gold fiducial markers and radiopaque hydrogel spacer per standard practice.
Medicina (Kaunas)
June 2024
Department of Neurosurgery, University of Marburg, 35037 Marburg, Germany.
: Microsurgical resection with intraoperative neuromonitoring is the gold standard for acoustic neurinomas (ANs) which are classified as T3 or T4 tumors according to the Hannover Classification. Microscope-based augmented reality (AR) can be beneficial in cerebellopontine angle and lateral skull base surgery, since these are small areas packed with anatomical structures and the use of this technology enables automatic 3D building of a model without the need for a surgeon to mentally perform this task of transferring 2D images seen on the microscope into imaginary 3D images, which then reduces the possibility of error and provides better orientation in the operative field. : All patients who underwent surgery for resection of ANs in our department were included in this study.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!