Angle-resolved low-coherence interferometry (a/LCI) measures depth-resolved angular scattering for cell nuclear morphology analysis. 2D a/LCI, developed to collect across two scattering planes, is currently limited by the lack of spatial scanning. Here we demonstrate 2D a/LCI scanning across a three-dimensional volume using an image rotation scheme and a scanning mirror. Validation using various optical phantoms demonstrated excellent scatterer size determination over a 7.5 mm linear range, for a total accessible area of ∼44 mm. Measurements from anisotropic scatterers allowed accurate determination of sizes and computation of aspect ratios. This scanning system will facilitate analysis of scatterer structure across wider tissue areas.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7449733PMC
http://dx.doi.org/10.1364/BOE.398052DOI Listing

Publication Analysis

Top Keywords

spatial scanning
8
angle-resolved low-coherence
8
low-coherence interferometry
8
anisotropic scatterers
8
scanning sample
4
sample two-dimensional
4
two-dimensional angle-resolved
4
interferometry analysis
4
analysis anisotropic
4
scatterers angle-resolved
4

Similar Publications

In image-guided radiotherapy (IGRT), four-dimensional cone-beam computed tomography (4D-CBCT) is critical for assessing tumor motion during a patients breathing cycle prior to beam delivery. However, generating 4D-CBCT images with sufficient quality requires significantly more projection images than a standard 3D-CBCT scan, leading to extended scanning times and increased imaging dose to the patient. To address these limitations, there is a strong demand for methods capable of reconstructing high-quality 4D-CBCT images from a 1-minute 3D-CBCT acquisition.

View Article and Find Full Text PDF

Tau exhibits change in both spatial extent and density of pathology along the Alzheimer's disease (AD) spectrum with each aspect contributing to the overall burden of pathological tau. Nevertheless, studies using Tau PET have measured either magnitude using standardized uptake value ratios (SUVRs) or extent using number of Tau+ regions. We hypothesized that combining these two dimensions into a single measure of Magnitude and eXtent, Tau-MaX, would provide improved quantification of global tau burden as well as allowing for a region-agnostic measure of global tau burden that does not require a pre-specified region of interest (ROI) or meta-ROI.

View Article and Find Full Text PDF

Understanding exposure risk using soil testing and GIS around an abandoned asbestos mine.

Ann Glob Health

January 2025

Department of Environmental and Occupational Health, Dornsife School of Public Health, Drexel University, Philadelphia, PA 19104 USA.

Abandoned asbestos mines are a potential source of environmental contamination and exposure for nearby residents. The asbestos exposure risk may persist even after the cessation of mining activity if the mine is not properly closed. One such abandoned mine is at Roro Hills in the Jharkhand state of India.

View Article and Find Full Text PDF

Coming home: how visually navigating ants (Myrmecia spp.) pinpoint their nest.

J Exp Biol

January 2025

Research School of Biology, The Australian National University, 46 Sullivans Creek Road, Canberra ACT2601, Australia.

Visually navigating Myrmecia foragers approach their nest from distances up to 25 m along well-directed paths, even from locations they have never been before ( Narendra et al., 2013). However, close to the nest, they often spend some time pinpointing the nest entrance, sometimes missing it by centimetres.

View Article and Find Full Text PDF

Digital detector PET/CT increases Centiloid measures of amyloid in Alzheimer's disease: A head-to-head comparison of cameras.

J Alzheimers Dis

January 2025

Health and Biosecurity, Commonwealth Scientific and Industrial Research Organisation, Brisbane, QLD, Australia.

Background: The introduction of therapeutics for Alzheimer's disease has led to increased interest in precisely quantifying amyloid-β (Aβ) burden for diagnosis, treatment monitoring, and further clinical research. Recent positron emission tomography (PET) hardware innovations including digital detectors have led to superior resolution and sensitivity, improving quantitative accuracy. However, the effect of PET scanner on Centiloid remains relatively unexplored and is assumed to be minimized by harmonizing PET resolutions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!