AI Article Synopsis

  • * A comprehensive review analyzed 58 studies from 2010 to 2019, examining the effectiveness of circulating miRNAs in diagnosing AMI with an overall pooled sensitivity of 82% and specificity of 87%.
  • * Specific panels of miRNAs show even higher diagnostic accuracy, with a three-miRNA panel achieving 91% sensitivity and 87% specificity, highlighting their potential as reliable biomarkers for AMI detection.

Article Abstract

Recent studies have shown that blood-based miRNAs are dysregulated in patients with acute myocardial infarction (AMI) and are therefore a potential tool for the diagnosis of AMI. Therefore, this study summarized and evaluated studies focused on microRNAs as novel biomarkers for the diagnosis of AMI from the last ten years. MEDLINE, the Cochrane Central database, and EMBASE were searched between January 2010 and December 2019. Studies that assessed the diagnostic accuracy of circulating microRNAs in AMI were chosen. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and area under the curve (AUC) were used to assess the test performance of miRNAs. A total of 58 studies that included 8,206 participants assessed the diagnostic accuracy of circulating miRNAs in AMI. The main results of the meta-analyses are as follows: (1) Total miRNAs: the overall pooled sensitivity and specificity were 0.82 (95% CI: 0.79-0.85) and 0.87 (95% CI: 0.84-0.90), respectively. The AUC value was 0.91 (95% CI: 0.88-0.93) in the overall summary receiver operator characteristic (SROC) curve. (2) The panel of two miRNAs: sensitivity: 0.88 (95% CI: 0.77-0.94), specificity: 0.84 (95% CI: 0.72-0.91), AUC: 0.92 (95% CI: 0.90-0.94). (3) The panel of three miRNAs: sensitivity: 0.91 (95% CI: 0.85-0.94), specificity: 0.87 (95% CI: 0.77-0.92), AUC: 0.92 (95% CI: 0.89-0.94). (4) Results by types of miRNAs: miRNA-1: sensitivity: 0.78 (95% CI: 0.71-0.84), specificity: 0.86 (95% CI: 0.77-0.91), AUC: 0.88 (95% CI: 0.85-0.90); miRNA-133a: sensitivity: 0.85 (95% CI: 0.69-0.94), specificity: 0.92 (95% CI: 0.61-0.99), AUC: 0.93 (95% CI: 0.91-0.95); miRNA-208b: sensitivity: 0.80 (95% CI: 0.69-0.88), specificity: 0.96 (95% CI: 0.77-0.99), AUC: 0.91 (95% CI: 0.88-0.93); miRNA-499: sensitivity: 0.85 (95% CI: 0.77-0.91), specificity: 0.95 (95% CI: 0.89-0.98), AUC: 0.96 (95% CI: 0.94-0.97). miRNAs may be used as potential biomarkers for the detection of AMI. For single, stand-alone miRNAs, miRNA-499 may have better diagnostic accuracy compared to other miRNAs. We propose that a panel of multiple miRNAs with high sensitivity and specificity should be tested.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7456928PMC
http://dx.doi.org/10.3389/fphys.2020.00691DOI Listing

Publication Analysis

Top Keywords

95%
21
diagnostic accuracy
12
sensitivity specificity
12
091 95%
12
092 95%
12
mirnas
11
sensitivity
9
specificity
9
acute myocardial
8
myocardial infarction
8

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!