Covid-19 was first reported in Iraq on February 24, 2020. Since then, to prevent its propagation, the Iraqi government declared a state of health emergency. A set of rapid and strict countermeasures have taken, including locking down cities and limiting population's mobility. In this study, concentrations of four criteria pollutants, NO, O, PM and PM before the lockdown from January 16 to February 29, 2020, and during four periods of partial and total lockdown from March 1 to July 24, 2020, in Baghdad were analysed. Overall, 6, 8 and 15% decreases in NO, PM, and PM concentrations, respectively in Baghdad during the 1st partial and total lockdown from March 1 to April 21, compared to the period before the lockdown. While, there were 13% increase in O for same period. During the 2nd partial lockdown from June 14 to July 24, NO and PM decreases 20 and 2.5%, respectively. While, there were 525 and 56% increase in O and PM, respectively for same period. The air quality index (AQI) improved by 13% in Baghdad during the 1st partial lockdown from March 1 to April 21, compared to its pre-lockdown. The results of NO tropospheric column extracted from the Sentinel-5P satellite shown the NO emissions reduced up to 35 to 40% across Iraq, due to lockdown measures, between January and July, 2020, especially across the major cities such as Baghdad, Basra and Erbil. The lockdown due to COVID-19 has drastic effects on social and economic aspects. However, the lockdown also has some positive effect on natural environment and air quality improvement.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7462443 | PMC |
http://dx.doi.org/10.1016/j.scitotenv.2020.141978 | DOI Listing |
Proc Natl Acad Sci U S A
January 2025
Department of Environmental Health, Harvard T. H. Chan School of Public Health, Boston, MA 02114.
Radon, a common radioactive indoor air pollutant, is the second leading cause of lung cancer in the United States. Knowledge about its distribution is essential for risk assessment and designing efficient protective regulations. However, the three current radon maps for the United States are unable to provide the up-to-date, high-resolution, and time-varying radon concentrations.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Medical Sciences, Cancer Epidemiology Unit, University of Turin and CPO-Piemonte, Turin, Italy.
Objectives: Maternal occupational exposures during early pregnancy can be detrimental to foetus health and have short- and long-term health effects on the child. This study examined their association with adverse birth outcomes.
Methods: The study included 3938 nulliparous women from the Italian NINFEA mother-child cohort.
Environ Sci Technol
January 2025
State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.
Air pollution is a leading contributor to the global disease burden. However, the complex nature of the chemicals to which humans are exposed through inhalation has obscured the identification of the key compounds responsible for diseases. Here, we develop a network topology-based framework to identify key toxic compounds in the airborne chemical exposome.
View Article and Find Full Text PDFInt J Biometeorol
January 2025
Department of Preventive Health, Shanxi Cardiovascular Hospital, No. 18 Yifen Street, Wanbailin District, Taiyuan, 030024, Shanxi Province, China.
Air pollution remains a significant threat to human health and economic development. Most previous studies have examined the health effects of individual pollutants, which often overlook the combined impacts of multiple pollutants. The traditional composite indicator air quality index (AQI) only focuses on the major pollutants, whereas the health risk-based air quality index (HAQI) could offer a more comprehensive evaluation of the health effects of various pollutants on populations.
View Article and Find Full Text PDFEnviron Monit Assess
January 2025
International Joint Research Center For Green Energy and Chemical Industry, School of Chemical Engineering, East China University of Science and Technology, Shanghai, 200237, People's Republic of China.
Escalating SOx and NOx emissions from industrial plants necessitates customized scrubbing solutions to improve removal efficiency and tackle cost limitations in existing wet FGD units. This work investigates the real-time intensified removal pathways via an innovative two-stage countercurrent spray tower configuration strategically integrating NaOH (M) and NaOH/NaClO (M/M) to remove SOx and NOx emissions simultaneously from the industrial stack through a comprehensive parametric study of absorbents concentration, reaction temperature, gas flow rate, liquid to gas ratio (F/F), and absorbent showering head. Flue gas stream comprising SO bearing 4500 ppm, SO bearing 300 ppm, 70 ppm NO, and 50 ppm NO brought into contact with two scrubbing solutions as M, and a complex absorbent of M/M at varying respective ratios.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!