Pupil diameter as a biomarker of effort in goal-directed gait.

Exp Brain Res

Department of Kinesiology, School of Public Health, Indiana University, 1025 E 7th Street, Bloomington, IN, 47405, USA.

Published: November 2020

AI Article Synopsis

  • Subjects' eye movements were tracked during walking while they performed tasks with varying cognitive loads, revealing significant changes in pupil diameter, fixation durations, and blinking patterns based on task difficulty.
  • Pupil diameter emerged as the strongest indicator of cognitive load during walking, outperforming other eye movement measures like fixation characteristics.
  • The study suggests that higher cognitive effort during gait can limit attention to environmental distractions, potentially increasing fall risk for individuals with lower attentional capacity.

Article Abstract

Subjects' eye movement behavior related to cognitive effort during gait was measured as subjects walked to perform low and high cognitive load tasks. We found that all pupil diameter measures, fixation durations, and the proportion of blink duration changed significantly during gait as a function of task load. In contrast, the number of fixations, saccade durations and travel time did not change significantly as a function of task load. Findings showed that pupil diameter was the best predictor of task load during one's gait preceding the performance of the task. While other studies have demonstrated the importance of eye fixation characteristics during gait, our findings showed that eye measures related to pupil diameter were better at detecting cognitive load while walking to perform a task compared to eye fixation data. We also found that cognitive effort was not limited to just the performance of the task, but that it was also exerted during one's gait preceding the performance of the task. Therefore, the additional attention demand caused by an increase in task complexity may result in less attentional resources being available to adequately handle distractions (such as obstacle avoidance) while walking to perform the task. Consequently, this may increase the likelihood of falls in those individuals with lower attentional capacity.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00221-020-05915-7DOI Listing

Publication Analysis

Top Keywords

pupil diameter
16
task load
12
performance task
12
task
9
cognitive effort
8
cognitive load
8
function task
8
one's gait
8
gait preceding
8
preceding performance
8

Similar Publications

Normalization of Retinal Birefringence Scanning Signals.

Sensors (Basel)

December 2024

Ophthalmic Instrumentation Development Lab, The Wilmer Eye Institute, The Johns Hopkins University School of Medicine, Wilmer 233, 600 N. Wolfe St., Baltimore, MD 21287, USA.

Signal amplitudes obtained from retinal scanning depend on numerous factors. Working with polarized light to interrogate the retina, large parts of which are birefringent, is even more prone to artifacts. This article demonstrates the necessity of using normalization when working with retinal birefringence scanning signals in polarization-sensitive ophthalmic instruments.

View Article and Find Full Text PDF

Purpose: A relative afferent pupillary defect (RAPD) is a characteristic clinical sign of optic neuritis (ON). Here, we systematically evaluated ultrasound pupillometry (UP) for the detection of an RAPD in patients with ON, including a comparison with infrared video pupillometry (IVP), the gold standard for objective pupillometry.

Materials And Methods: We enrolled 40 patients with acute (n = 9) or past (n = 31) ON (ON+), 31 patients with multiple sclerosis (MS) without prior ON, and 50 healthy controls (HC) in a cross-sectional observational study.

View Article and Find Full Text PDF

Pupil responses are commonly used to provide insight into visual perception, autonomic control, cognition, and various brain disorders. However, making inferences from pupil data can be complicated by nonlinearities in pupil dynamics and variability within and across individuals, which challenge the assumptions of linearity or group-level homogeneity required for common analysis methods. In this study, we evaluated luminance evoked pupil dynamics in young healthy adults (n = 10, M:F = 5:5, ages 19-25 years) by identifying nonlinearities, variability, and conserved relationships across individuals to improve the ability to make inferences from pupil data.

View Article and Find Full Text PDF

Motor vehicle accidents (MVA) are the leading cause of death in childhood and young adult age. One of the most important factors behind MVA is driving under the influence of alcohol (DUIA) and drugs (DUID). The importance of DUID is rising together with the increasing drug abuse.

View Article and Find Full Text PDF

Visual Performance Correlation with Corneal Aberrometric Profile and Pupil Size After Implantation of a Trifocal Hydrophobic IOL.

Clin Ophthalmol

December 2024

Département de Recherche Clinique, Institut Ophtalmologique de l'Ouest (IOO) Jules Verne, Nantes, France.

Purpose: To evaluate clinical outcomes obtained after cataract surgery involving the implantation of a trifocal hydrophobic intraocular lens (IOL) and to determine if pupil size and the corneal aberrometric profile correlate to visual acuity at different distances.

Methods: 49 patients (98 eyes) underwent bilateral cataract surgery with the placement of FineVision HP IOLs for presbyopia and were assessed at 1- and 3- to 6-months post-surgery. Postoperatively, refraction, monocular and binocular uncorrected and corrected distance visual acuity (UDVA and CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA) and the binocular defocus curve were measured.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!