Statement Of Problem: A consensus on the clinical performance in dental implants placed with different insertion torques is lacking.
Purpose: The purpose of this systematic review and meta-analysis was to evaluate the effect of high insertion torque compared with regular or low torques during dental implant placement in terms of implant survival rate and marginal bone loss.
Material And Methods: Two independent reviewers searched electronic databases for studies published until April 2019. The population, intervention, comparison, outcome (PICO) question was "Do patients who receive implants with a high torque (equal or higher than 50 Ncm) show similar implant survival rates and marginal bone loss as compared with those who receive implants with a regular or low torque (less than 50 Ncm)?". The meta-analysis was based on the Mantel-Haenszel (MH) and the inverse variance (IV) methods (α=.05).
Results: The search yielded 6 articles, which included 389 patients (mean age: 55.28 years) who had received 651 dental implants (437 with high torque and 214 with low or regular torque). Most studies evaluated delayed loading, except 1 study that evaluated immediate implant loading (n=50 for each group). Low or regular insertion torque had a high failure rate (4.2%) compared with high insertion torque (1.1%), chiefly because of immediate loading. However, the meta-analysis indicated no significant difference between high- and regular- or low-torque implant placement in implant survival rate (P=.52, risk ratio [RR]: 0.51, 95% confidence interval [CI]: 0.06-4.06) and marginal bone loss (P=.30, mean difference [MD]: 0.15, 95% CI: -0.14 to 0.44).
Conclusions: A high insertion torque during implant placement does not affect implant survival rate or marginal bone loss. However, further research is recommended to reassess this clinical performance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2020.06.012 | DOI Listing |
J Craniofac Surg
December 2024
Department of Oral and Maxillofacial Surgery, College of Dentistry, King Saud University.
Objectives: This study aimed to evaluate the osseointegration properties of titanium bone implants coated with carob-mediated calcium hydroxide nanoparticles biomechanically, radiographically, and histologically on rabbit tibias.
Material And Methods: Forty coated and forty uncoated titanium alloy bone implants were inserted into 20 New Zealand rabbits; each tibia received 2 implants. The rabbits were sacrificed after 4 or 8 weeks, and samples were retrieved for biomechanical evaluation through removal torque test to assess the bond between implant and bone, radiographic evaluation through microcomputed tomography analysis to compare the bone-to-implant contact percentage and bone volume of the peri-implant area, scanning electron microscopic and histologic evaluation through hematoxylin and eosin stain.
Front Bioeng Biotechnol
December 2024
Department of Spine Surgery, The Affiliated Hospital of Qingdao University, Qindao, China.
Background: Lumbar degenerative diseases are an important factor in disability worldwide, and they are also common among the elderly population. Stand-Alone Oblique Lumbar Interbody Fusion (Stand-Alone OLIF) is a novel surgical approach for treating lumbar degenerative diseases. However, long-term follow-up after surgery has revealed the risk of endplate collapse associated with Stand-Alone OLIF procedures.
View Article and Find Full Text PDFEur J Orthod
December 2024
Department of Dentistry, All India Institute of Medical Sciences, Basni Industrial Area Phase-2, Jodhpur- 342005, Rajasthan, India.
Background: The infrazygomatic miniscrew implants (IZC-MSI) serve as innovative temporary anchorage devices placed parallel to the roots of molars in the infrazygomatic crest region, leveraging their extra-radicular location to support the en masse distalization and intrusion of the maxillary dentition. The efficacy and stability of these screws are crucial for their application in contemporary orthodontic practices.
Objectives: This systematic review aimed to estimate the success rate and factors affecting the stability of IZC-MSI.
Adv Sci (Weinh)
December 2024
School of Electronic Science and Engineering, Nanjing University, Nanjing, 210023, China.
The prevailing research emphasis has been on reducing the critical switching current density (J) by enhancing the damping-like efficiency (β). However, recent studies have shown that the field-like efficiency (β) can also play a major role in reducing J. In this study, the central inversion asymmetry of Pt-Co is significantly enhanced through interface engineering at the sub-atomic layer of Ta, thereby inducing substantial alterations in the β associated with the interface.
View Article and Find Full Text PDFClin Implant Dent Relat Res
December 2024
Department of Medical, Surgical and Health Sciences, University of Trieste, Trieste, Italy.
Introduction: Short implants are today a reliable, minimally invasive option for the rehabilitation of the posterior maxilla. However, maintaining marginal bone stability remains a crucial factor for long-term success, particularly in the case of short implants. The present multicenter prospective case-control study aimed to compare the clinical outcomes of bone-level and tissue-level short implants in the posterior maxilla, focusing on implant survival and peri-implant marginal bone stability over 1 year of function.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!