A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Endoscopic sleeve gastroplasty with argon plasma coagulation: A novel technique. | LitMetric

Endoscopic sleeve gastroplasty with argon plasma coagulation: A novel technique.

J Dig Dis

Department of Medicine, Division of Gastroenterology and Hepatology, Johns Hopkins Medical Institutions, Baltimore, Maryland, USA.

Published: November 2020

AI Article Synopsis

  • Endoscopic sleeve gastroplasty (ESG) is a minimally invasive weight-loss surgery that can face issues like suture dehiscence and stomach enlargement, but combining it with argon plasma coagulation (APC) might improve its effectiveness.
  • A case study of a 46-year-old woman who underwent ESG with APC showed successful results, including a 14.5% weight loss and improved structure of the stomach after 6 months.
  • Further research is required to assess the long-term benefits and potential recommendations of combining these two procedures.

Article Abstract

Objective: The endoscopic sleeve gastroplasty (ESG) is a minimally invasive procedure in which the anterior and posterior aspects of the greater curvature are stitched endoscopically, producing a sleeve-like anatomy mimicking that in a sleeve gastrectomy. However, suture dehiscence and enlargement of the stomach within months of the procedure have been observed. Argon plasma coagulation (APC) is widely used in gastrointestinal endoscopy and is able to induce scarring and fibrosis. We coupled ESG with APC to evaluate its potential to improve durability.

Methods: A 46-year-old woman with obesity presented for ESG. Her pre-procedure weight was 117 kg with a body mass index (BMI) of 41.4 kg/m . After each plication was complete, APC (60 W, argon flow rate 1.2 L/min) was used to ablate the mucosal surface of the exposed plicated mucosa. APC was applied until the mucosal color was dark brown, indicating adequate and successful mucosal and submucosal ablation.

Results: The procedure was successful, and the patient recovered without peri- or post-operative complications. The procedure time was 47 minutes. A total of seven sutures were used. At 6-month follow-up the patient had lost 17 kg (37.5 lbs), equivalent to 14.5% total weight loss and had a BMI of 35.4 kg/m . Endoscopic follow-up at 6 months revealed enhanced fibrosis along the plications, resulting in a superior, sleeve-like lumen.

Conclusions: The combination of ESG with APC may act synergistically to reduce weight without adding significant procedure time. Further investigation is needed to determine whether it should be widely recommended.

Download full-text PDF

Source
http://dx.doi.org/10.1111/1751-2980.12939DOI Listing

Publication Analysis

Top Keywords

endoscopic sleeve
8
sleeve gastroplasty
8
argon plasma
8
plasma coagulation
8
esg apc
8
procedure time
8
procedure
5
apc
5
gastroplasty argon
4
coagulation novel
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!