Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The Sedentary Behavior Questionnaire (SBQ) is a brief and easy instrument to measure time spent on sedentary activities; however, no study has investigated the reliability and validity of this questionnaire in people with chronic low back pain (LBP).
Objective: To investigate the internal consistency, test-retest reliability, measurement error, construct validity, and interpretability of the SBQ against data derived from an accelerometer in patients with nonspecific chronic LBP.
Study Design: Cross-sectional study.
Setting: Outpatient physiotherapy clinic.
Patients: Seventy-five patients aged between 18 and 60 years (mean age, 42 years old) with nonspecific chronic LBP were recruited for this study.
Interventions: Not applicable.
Methods: The Cronbach's α was calculated to investigate the internal consistency of the SBQ and the intraclass correlation coefficient (ICC) was calculated to investigate the reliability of the SBQ between two administrations separated by a 1-week interval. Measurement error was assessed calculating the SEM and minimal detectable change (MDC). Spearman correlation (r) was calculated to investigate the construct validity using hypothesis testing. Interpretability was investigated using ceiling and floor effects.
Results: The Cronbach's α of the SBQ total score was 0.92, indicating homogeneity among the items of the instrument. The reliability of the SBQ was excellent (ICC > 0.75), without any evidence of ceiling and floor effects. Regarding measurement error, the total score of the SBQ showed an SEM and MDC of 109.8 minutes per day and 304.4 minutes per day, respectively. However, there were no correlations of the SBQ domains or the total score with the accelerometer-measured sedentary time (r < 0.25).
Conclusion: The SBQ is a reliable tool for quantifying time spent in sedentary activities of patients with chronic LBP. The SBQ showed poor construct validity compared to the accelerometer-measured sedentary time, which indicates that patients may underestimate their time spent in sedentary activities.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/pmrj.12490 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!