Multiplexed, high-throughput analysis facilitates therapeutic drug monitoring. 14 drugs with various physico-chemical properties were quantitated in dried blood microsamples. Analytes were extracted employing eight solvent compositions and seven extraction methods. The applicability of liquid serum, dried serum and dried whole blood calibrators was investigated. High recoveries were attained. Calibration using dried serum yielded lowest total error. Reducing sample hematocrit caused outstanding elevations in recovery of analytes with high polarity or affinity to erythrocytes. 9-day analyte stability was demonstrated. Based on the analysis of spiked samples, multiplexed testing of drugs in dried blood microsamples seems feasible, but with analyte-dependent method performance. Dried serum calibration allows the adaptation of serum-based workflows. Further evaluation using real-life specimens is needed.