Objective: Conservative treatment with a vacuum bell (VB) for pectus excavatum (PE) has now been gradually popularized as an alternative to surgery. We describe our initial experience with a novel three dimensional (3D) printed VB device.

Methods: Prospectively collected data of all patients who started using a 3D printed VB in 2018 at our institution were analyzed. Linear and logistic regressions were used to identify factors associated with effectiveness of device usage.

Results: In total, forty-two patients with a median age of 3.6 years were treated with the device. The median follow-up duration was 11.1 months and the mean initial Depth Ratio (DR) was 0.129. There were no permanent sequelae from side effects. Thirty patients with at least one follow-up body scan data showed varying improvement (z = - 4.569, p = 0.0000). Linear regression suggested that longer usage improved outcomes (R = 0.235, p = 0.014). By logistic regression there was a trend of younger ages and less initial DR for better improvement though neither was statistically significant (p = 0.086, 0.078, respectively).

Conclusion: Our initial experience has shown the 3D printed VB may be as effective as other conventional VBs and could be used as an alternative to surgical treatment for selected patients with PE. More experience and studies with this type of VB are needed to demonstrate its superiority with regard to the 3D printing design and optimal timing and indication for use.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7488022PMC
http://dx.doi.org/10.1186/s13019-020-01276-yDOI Listing

Publication Analysis

Top Keywords

vacuum bell
8
bell pectus
8
pectus excavatum
8
initial experience
8
novel three-dimensional
4
printed
4
three-dimensional printed
4
printed vacuum
4
excavatum treatment
4
treatment preliminary
4

Similar Publications

Surgical Algorithm of Poland Syndrome Based on Thorax, Breast, and Nipple-areola Complex Classification.

Plast Reconstr Surg Glob Open

November 2024

From the Department of Pediatric Surgery, IRCCS Istituto Giannina Gaslini, Genoa, Italy.

Background: Poland syndrome (PS) is a rare congenital syndrome characterized by unilateral pectoralis major muscle defect. In 2016, we proposed the thorax, breast, and nipple-areola complex (TBN) classification and a subsequent treatment algorithm, which included conservative and surgical procedures. Our aim is to report the results we obtained treating all thoracic anomalies according to the proposed algorithm in a cohort of adolescents affected by PS.

View Article and Find Full Text PDF

The nonclassicality of a macroscopic single-mode optical superposition state is potentially convertible into entanglement, when the state is mixed with the vacuum on a beam splitter. Considering light beams with polarization degree of freedom in Euclidean space as coherent product states in a bipartite Hilbert space, we propose a method to convert the two orthogonal polarizations into simultaneous entanglement and classical nonseparability through nonclassicality in the superpositions of coherent and displaced Fock states. Equivalent Bell state emerges from the resulted superpositions and the proportion of mixed entanglement and nonseparablity is determined by the displacement amplitudes along the polarization directions.

View Article and Find Full Text PDF

Reply to Miguel Lia Tedde.

Eur J Cardiothorac Surg

November 2024

Department of Cardiothoracic Surgery, James Cook University Hospital, Middlesbrough, UK.

View Article and Find Full Text PDF

A mathematical model for vacuum evaporation process was developed, which was experimentally validated at different initial pHs and temperatures for ammonia removal from anaerobically digested sludge. Six scenarios were evaluated by combining vacuum evaporation process with anaerobic digestion using anaerobic digestion model 1. These scenarios included a control, a pretreatment by vacuum evaporation, a post-treatment by vacuum evaporation at pH 9, a post-treatment by conventional evaporation (100 °C), an intensification with vacuum-concentrated recycled digestate back to the digester, and a second intensification at pH 9.

View Article and Find Full Text PDF

Vacuum Bell Therapy for Pectus Excavatum: Long-term Experience at a Single Center.

J Pediatr Surg

October 2024

Macon and Joan Brock Virginia Health Sciences at Old Dominion University, Department of Surgery, P.O. Box 1980, Norfolk, VA, 23501, United States; Children's Hospital of the King's Daughters, 601 Children's Lane, Norfolk, VA, 23507, United States. Electronic address:

Aim: To evaluate factors associated with excellent correction in pectus excavatum patients undergoing vacuum bell therapy (VBT).

Methods: A single-institution retrospective chart review was performed November 2012-April 2023 to assess corrections of patients who underwent VBT. Patient demographics, presentation, and results were collected.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!