Permanent His Bundle Pacing Implantation Facilitated by Visualization of the Tricuspid Valve Annulus.

Circ Arrhythm Electrophysiol

The Cardiac Arrhythmia Center, State Key Laboratory of Cardiovascular Disease, National Clinical Research Center of Cardiovascular Diseases, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China (M.G., H.N., Y.H., X.L., N.Z., M.C., X.C., W.H., S.Z.).

Published: October 2020

Background: His bundle pacing (HBP) is the most physiological pacing modality. However, HBP has longer procedure times with frequent high capture thresholds, which likely contributes to the low adoption of this approach. The aim of this study is to compare HBP implantation with a novel imaging technique versus the standard implantation technique.

Methods: This study included 50 patients with standard pacing indications randomized to HBP with visualization of the tricuspid valve annulus (N=25, the visualization group) or with the standard method (N=25, the control group). In the visualization group, the tricuspid valve annulus was imaged by contrast injection in the right ventricle during fluoroscopy. The site for HBP was identified in relationship to the tricuspid septal leaflet and interventricular septum.

Results: Permanent HBP was successful in 92% in the visualization group and 88% in the control group. The fluoroscopic time for HBP lead placement was significantly shorter in the visualization group (7.1±3.3 minutes) compared with the control group (10.1±5.6 minutes, =0.03). Total procedural and fluoroscopic times were also significantly shorter in the visualization group (91.0±15.7 and 9.6±3.8 minutes) than the control group (104.4±17.8 and 12.7±6.2 minutes, =0.01 and 0.04, respectively). There was no significant difference in capture threshold between groups. In the visualization group, there was a quantitative association between the HBP site and the tricuspid valve annulus.

Conclusions: The visualization technique shortens the procedural and fluoroscopic times for HBP implantation. Moreover, anatomic localization of HBP sites is strongly associated with physiological characteristics of pacing, which can help guide optimal lead placement. Registration: URL: https://www.chictr.org.cn/index.aspx. Unique identifier: ChiCTR2000029834.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCEP.120.008370DOI Listing

Publication Analysis

Top Keywords

visualization group
24
tricuspid valve
16
control group
16
valve annulus
12
hbp
10
group
10
visualization
9
bundle pacing
8
visualization tricuspid
8
hbp implantation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!