SARS-CoV-2 is a single-stranded RNA virus classified in the family . In this review, we summarize the literature on light-based (UV, blue, and red lights) sanitization methods for the inactivation of ssRNA viruses in different matrixes (air, liquid, and solid). The rate of inactivation of ssRNA viruses in liquid was higher than in air, whereas inactivation on solid surfaces varied with the type of surface. The efficacy of light-based inactivation was reduced by the presence of absorptive materials. Several technologies can be used to deliver light, including mercury lamp (conventional UV), excimer lamp (UV), pulsed-light, and light-emitting diode (LED). Pulsed-light technologies could inactivate viruses more quickly than conventional UV-C lamps. Large-scale use of germicidal LED is dependent on future improvements in their energy efficiency. Blue light possesses virucidal potential in the presence of exogenous photosensitizers, although femtosecond laser (ultrashort pulses) can be used to circumvent the need for photosensitizers. Red light can be combined with methylene blue for application in medical settings, especially for sanitization of blood products. Future modelling studies are required to establish clearer parameters for assessing susceptibility of viruses to light-based inactivation. There is considerable scope for improvement in the current germicidal light-based technologies and practices.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7558314 | PMC |
http://dx.doi.org/10.3390/pathogens9090737 | DOI Listing |
J Photochem Photobiol B
February 2025
Department of Ophthalmology, Aotearoa New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand. Electronic address:
Purpose: Preclinical studies have confirmed the safety and efficacy of narrowband low-intensity ultraviolet C light (UVC) in managing bacterial corneal infection. To further consolidate these findings, the present study aimed to explore in vitro anti-biofilm efficacy of low-intensity UVC light for its potential use in biofilm-related infections.
Methods: Pseudomonas aeruginosa biofilm was grown in chamber well slides for 48 h and exposed to one of the following challenges: UVC (265 nm wavelength, intensity 1.
Sci Rep
December 2024
Division of Blood Components and Devices, Center for Biologics Evaluation and Research, FDA, Silver Spring, MD, 20993, USA.
Added safety measures coupled with the development and use of pathogen reduction technologies (PRT) significantly reduces the risk of transfusion-transmitted infections (TTIs) from blood products. Current approved PRTs utilize chemical and/or UV-light based inactivation methods. While the effectiveness of these PRTs in reducing pathogens are well documented, these can cause tolerable yet unintended consequences on the quality and efficacy of the transfusion products.
View Article and Find Full Text PDFFood Res Int
January 2025
College of Food Science and Nutritional Engineering, Key Laboratory of Fruit and Vegetable Processing of Ministry of Agriculture and Rural Affairs, Beijing Key Laboratory for Food Non-Thermal Processing, China Agricultural University, Beijing 100083, PR China. Electronic address:
Frequent outbreaks caused by foodborne pathogens pose long-term risks to consumer health. To proactively reduce the load of pathogenic bacteria during food processing, a novel light-based antibacterial approach was developed by sequential application of 365 nm and 420 nm light-emitting diodes (LEDs). Results demonstrated that after treatment with 365 nm (480 J/cm) followed by 420 nm (307.
View Article and Find Full Text PDFFood Microbiol
March 2025
Department of Food Science and Human Nutrition, University of Illinois Urbana-Champaign, Urbana, IL, 61801, United States; Center for Digital Agriculture, University of Illinois Urbana-Champaign, Urbana, IL, 61801, United States. Electronic address:
The safety of ready-to-eat (RTE) deli meats, especially those sliced in retail establishments, may be improved by light-based surface decontamination. Conventional 254 nm ultraviolet-C (UVC) systems have strong germicidal effects but pose human-health hazards that make them unsuitable for retail use. This study therefore explores the efficacy of microplasma-based 222 nm far-UVC lamps as a safer alternative for decontaminating liquid buffer, two common food-contact surfaces (polyethylene terephthalate and stainless steel), and RTE turkey breast.
View Article and Find Full Text PDFWater Res
December 2024
Department of Civil, Environmental, and Architectural Engineering, University of Colorado Boulder, 4001 Discovery Dr., Boulder, CO 80303, United States. Electronic address:
Biofilms have been widely detected in water distribution and water storage systems posing potential risks to drinking water safety by harboring and shedding pathogens. Light-based disinfection methods, such as germicidal ultraviolet (UV) and antimicrobial blue light (aBL), could serve as non-chemical alternatives for biofilm control. This study investigated the inactivation of pure-culture Pseudomonas aeruginosa biofilms and mixed-culture biofilms using three distinct light-based disinfection methods: a low-pressure (LP) UV lamp emitting at 254 nm, a UV light emitting diode (LED) at 270 nm, and an aBL LED at 405 nm.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!