Aims: Shear wave elastosonography (SWE) is a non-invasive ultrasound imaging modality used to assess the mechanical properties of tissues such as rigidity and elasticity. In this prospective study, we investigated the effect of laparoscopic varicocelectomy on the elasticity, degree of fibrosis and function of the testes through SWE and we evaluated the correlation with semen parameters and histology findings.

Methods: Male patients with monolateral left varicocele and progressive alteration of the semen quality were enrolled prospectively. Patients were evaluated before varicocelectomy, 3 and 6 months after surgery with semen analysis, ecocolordoppler US and SWE. In all patients, a left testicular biopsy was performed at the time of varicocelectomy and it was repeated after 6 months in 55% of patients in order to investigate the histological findings and to correlate with SWE results.

Results: The study was conducted on 82 patients. SWE showed a statistically significant difference between left and right testicles. Three months after surgery the mean left testicular volume increased, mean left SWE features decreased, and sperm count increased (P values < .0001). The SWE parameters, testicular volume and semen analysis values showed a statistically significant positive correlation between the pre and postoperative results (P value < .0001). The histological alterations were significantly changed 6 months postoperative with a complete morphology recovery in accordance with SWE results.

Conclusions: SWE showed a statistically significant positive correlation with testicular volume, semen analysis and histological findings. This study represents the first investigation that correlates the varicocele, the testis volume, the quality of the seminal fluid ant the histological findings with the ultrasound and SWE values.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ijcp.13699DOI Listing

Publication Analysis

Top Keywords

shear wave
8
prospective study
8
correlation semen
8
semen parameters
8
histological findings
8
left testicular
8
patients
6
swe
6
left
5
wave elastography
4

Similar Publications

Background: The paratenon has been shown to promote Achilles tendon healing, but the evidence supporting the role of paratenon protection technique in Achilles tendon repair is sparse. We retrospectively assessed the results of a paratenon-sparing repair technique vs an open giftbox repair of Achilles tendon ruptures.

Methods: Patients with Achilles tendon rupture who underwent surgical treatment at our hospital between January 2015 and August 2021 were retrospectively reviewed.

View Article and Find Full Text PDF

Shear Wave Elastography (SWE) is an imaging technique that detects shear waves generated by tissue excited by Acoustic Radiation Force (ARF), and characterizes the mechanical properties of soft tissue by analyzing the propagation velocity of shear wave. ARF induces a change in energy density through the nonlinear propagation of ultrasound waves, which drives the tissue to generate shear waves. However, the amplitude of shear waves generated by ARF is weak, and the shear waves are strongly attenuated in vivo.

View Article and Find Full Text PDF

Background: When papillary thyroid carcinoma (PTC) is accompanied by Hashimoto's thyroiditis (HT), it is often challenging for preoperative ultrasound to distinguish between central lymph node enlargement caused by PTC metastasis and inflammatory reaction due to HT. However, central lymph node metastasis (CLNM) is closely associated with the risk of PTC recurrence after surgery. In this study, we developed a model to predict in patients with PTC combined with HT, based on conventional ultrasound characteristics and shear wave elastography (SWE) quantitative parameters of the primary lesion.

View Article and Find Full Text PDF

Underwater sound propagation over a layered seabed with weak shear rigiditya).

J Acoust Soc Am

January 2025

Department of Physics, Naval Postgraduate School, 833 Dyer Road, Monterey, California 93943-5216, USA.

The shear wave speed is often small compared to the compressional wave speed in the top part of the seabed, where acoustic normal modes penetrate. In sediments with weak but finite shear rigidity, the strongest conversion from compressional to shear waves occurs at interfaces within the sediment. Shear wave generation at such interfaces and interference within sediment layers lead to first-order perturbations in the normal mode phase speed and contributions to sound attenuation, which vary rapidly with frequency.

View Article and Find Full Text PDF

Background: The objective of this study was to comprehensively review the literature on Shear Wave Elastography (SWE), a non-invasive imaging technique prevalent in medical ultrasound. SWE is instrumental in assessing superficial glandular tissues, abdominal organs, tendons, joints, carotid vessels, and peripheral nerve tissues, among others. By employing bibliometric analysis, we aimed to encapsulate the scholarly contributions over the past two decades, identifying key research areas and tracing the evolutionary trajectory of SWE.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!