A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

CPAP combined with oral appliance therapy reduces CPAP requirements and pharyngeal pressure swings in obstructive sleep apnea. | LitMetric

Oral appliance (OA) therapy is the leading alternative to continuous positive airway pressure (CPAP) for obstructive sleep apnea (OSA). It is well tolerated compared with CPAP. However, ≥50% of patients using OA therapy have incomplete resolution of their OSA. Combination therapy with CPAP and oral appliance (CPAP + OA) is a potential alternative for incomplete responders to OA therapy. This study aimed to determine the extent to which combination therapy reduces therapeutic CPAP requirements using gold-standard physiological methodology in those who have an incomplete response to OA therapy alone. Sixteen incomplete responders [residual apnea/hypopnea index (AHI) > 10 events/h] to a novel OA with a built-in oral airway were recruited (3 women:13 men, aged 31-65 yr, body mass index: 22-38 kg/m, residual AHI range: 13-63 events/h). Participants were fitted with a nasal mask, pneumotachograph, epiglottic pressure catheter, and standard polysomnography equipment. CPAP titrations were performed during non-rapid eye movement (NREM) supine sleep in each participant during three conditions (order randomized): CPAP only, CPAP + OA (oral airway open), and CPAP + OA (oral airway closed). OSA was resolved at pressures of 4 ± 2 and 5 ± 2 cmHO during CPAP + OA (oral airway open) and CPAP + OA (oral airway closed) conditions versus 8 ± 2 cmHO during CPAP only ( < 0.01). Negative epiglottic pressure swings in oral airway open and closed conditions were normalized to CPAP only levels [-2.5(-3.7, -2.6) vs. -2.3(-3.2, -2.4) vs. -2.1(-2.7, -2.3) cmHO]. Combined CPAP and OA therapy reduces therapeutic CPAP requirements by 35%-45% and minimizes epiglottic pressure swings. This combination may be a therapeutic alternative for patients with incomplete responses to OA therapy alone and those who cannot tolerate high CPAP levels. Combined CPAP and oral appliance therapy has been suggested as an alternative for incomplete responders to oral appliance therapy. We used a novel oral appliance incorporating an oral airway together with CPAP to show that pharyngeal pressure swings were normalized at reduced CPAP levels. Our findings demonstrate that using CPAP and oral appliance together may be a beneficial alternative for incomplete responders to oral appliance therapy and intolerant CPAP users due to high-pressure requirements.

Download full-text PDF

Source
http://dx.doi.org/10.1152/japplphysiol.00393.2020DOI Listing

Publication Analysis

Top Keywords

oral appliance
32
cpap oral
28
oral airway
28
cpap
23
appliance therapy
20
pressure swings
16
incomplete responders
16
oral
15
therapy
12
therapy reduces
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!