Unlabelled: An 81-year-old man complaining of exertional dyspnoea underwent coronary angiography using an iodinated contrast medium. After angiography, the patient required systemic corticosteroid therapy because of respiratory failure due to alveolar haemorrhage. Percutaneous coronary intervention was performed 29 days after angiography using the same contrast medium. After the intervention, the patient required intubated mechanical ventilation and renal replacement therapy. Bronchoalveolar lavage was bloody with many haemosiderin-filled macrophages. Systemic corticosteroid therapy again improved his clinical condition. Iodinated contrast media may cause alveolar haemorrhage and re-exposure to contrast media may induce a more severe adverse reaction.

Learning Points: Iodinated contrast media may cause alveolar haemorrhage.Re-exposure to iodinated contrast media may induce a more severe adverse reaction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7473693PMC
http://dx.doi.org/10.12890/2020_001744DOI Listing

Publication Analysis

Top Keywords

iodinated contrast
20
contrast media
16
alveolar haemorrhage
12
contrast medium
12
patient required
8
systemic corticosteroid
8
corticosteroid therapy
8
media alveolar
8
media induce
8
induce severe
8

Similar Publications

Diagnostic value of dual-layer spectral detector CT parameters for differentiating high- from low-grade bladder cancer.

Insights Imaging

January 2025

Department of Radiology, State Key Laboratory of Complex Severe and Rare Disease, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, People's Republic of China.

Objectives: This study aimed to investigate the diagnostic value of spectral parameters of dual-layer spectral detector computed tomography (DLCT) in distinguishing between low- and high-grade bladder cancer (BCa).

Methods: This single-center retrospective study included pathologically confirmed BCa patients who underwent preoperative contrast-enhanced DLCT. Patients were divided into low- and high-grade groups based on pathology.

View Article and Find Full Text PDF

Objectives: A recent coronavirus-related factory shutdown led to a global shortage of iodinated contrast. The authors evaluated how the contrast shortage impacted percutaneous coronary interventions (PCI).

Methods: Using a statewide database incorporating CathPCI registry data from 19 hospitals, the authors evaluated 2 time periods: pre-shortage (May 1, 2021 - April 30, 2022) and during the shortage (May 1, 2022 - October 31, 2022).

View Article and Find Full Text PDF

Sentinel lymph node (SLN) mapping has been shown to be important for staging in dogs with mast cell tumors (MCTs). Despite this, many patients are referred to an oncologist after surgical intervention has been carried out. It is unknown whether lymphatic drainage patterns are altered by surgery and whether postoperative SLN mapping can be reliably conducted.

View Article and Find Full Text PDF

Purpose: To assess and compare the diagnostic efficiency of histogram analysis of monochromatic and iodine images derived from spectral CT in predicting Ki-67 expression in gastric gastrointestinal stromal tumors (gGIST).

Methods: Sixty-five patients with gGIST who underwent spectral CT were divided into a low-level Ki-67 expression group (LEG, Ki-67 < 10%, n = 33) and a high-level Ki-67 expression group (HEG, Ki-67 ≥ 10%, n = 32). Conventional CT features were extracted and compared.

View Article and Find Full Text PDF

Artefacts and diagnostic pitfalls in contrast-enhanced mammography: a pictorial review.

Clin Radiol

November 2024

Department of Radiology and Nuclear Medicine, Tuen Mun Hospital, 23 Tsing Chung Koon Road, Tuen Mun, N.T, Hong Kong; Department of Radiology, Pok Oi Hospital, Au Tau, Yuen Long, N.T., Hong Kong.

Contrast-enhanced mammography (CEM) is an advanced emerging imaging technique that uses iodine contrast medium to improve breast cancer detection. Understanding CEM artefacts and pitfalls is important to prevent diagnostic misinterpretation. This article aims to provide a comprehensive review of the artefacts and potential diagnostic pitfalls encountered in CEM, focusing on their characteristic imaging features and strategies to mitigate these issues.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!