Advances in the Study of Lens Refilling.

J Ophthalmol

Department of Ophthalmology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing 210008, China.

Published: August 2020

AI Article Synopsis

  • * Various accommodative intraocular lenses (IOLs) and surgical methods have been proposed for cataract surgery, but they often result in poor accommodation after the procedure.
  • * A technique involving the refilling of the lens with a special injectable polymer shows promise, but challenges such as post-surgery capsule opacification and inconsistent accommodative power have hindered its widespread clinical use.

Article Abstract

The ultimate goal of cataract surgery is to restore the accommodation while restoring distance visual acuity. Different kinds of accommodative intraocular lens (IOLs) and surgical techniques have been suggested to apply during the surgery, but they showed poor postoperative accommodation. It is possible to achieve this goal by refilling the lens with an injectable polymer. We present a summary of the existing materials, methods, results, and some obstacles in clinical application that remain of lens refilling for restoration of accommodation. Two main problems have restricted the clinical application of this technique. One was the formation of postoperative secondary capsule opacification and the other was the different accommodative power after surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7471792PMC
http://dx.doi.org/10.1155/2020/8956275DOI Listing

Publication Analysis

Top Keywords

lens refilling
8
clinical application
8
advances study
4
lens
4
study lens
4
refilling ultimate
4
ultimate goal
4
goal cataract
4
cataract surgery
4
surgery restore
4

Similar Publications

Background: While key to interpreting findings and assessing generalizability, implementation fidelity is underreported in mobile health (mHealth) literature. We evaluated implementation fidelity of an opt-in, hybrid, two-way texting (2wT) intervention previously demonstrated to improve 12-month retention on antiretroviral therapy (ART) among people living with HIV (PLHIV) in a quasi-experimental study in Lilongwe, Malawi.

Methods: Short message service (SMS) data and ART refill visit records were used to evaluate adherence to 2wT content, frequency and duration through the lens of the Conceptual Framework for Implementation Fidelity.

View Article and Find Full Text PDF

Background: While key to interpreting findings and assessing generalizability, implementation fidelity is underreported in mobile health (mHealth) literature. We evaluated implementation fidelity of an opt-in, hybrid, two-way texting (2wT) intervention previously demonstrated to improve 12-month retention on antiretroviral therapy (ART) among people living with HIV (PLHIV) in a quasi-experimental study in Lilongwe, Malawi.

Methods: Short message service (SMS) data and ART refill visit records were used to evaluate adherence to 2wT content, frequency and duration through the lens of the Conceptual Framework for Implementation Fidelity.

View Article and Find Full Text PDF

BCLA CLEAR presbyopia: Management with intraocular lenses.

Cont Lens Anterior Eye

August 2024

College of Health & Life Sciences, Aston University, Birmingham, United Kingdom. Electronic address:

Cataract surgery including intraocular lens (IOL) insertion, has been refined extensively since the first such procedure by Sir Harold Ridley in 1949. The intentional creation of monovision with IOLs using monofocal IOL designs has been reported since 1984. The first reported implantation of multifocal IOLs was published in 1987.

View Article and Find Full Text PDF

Background: Electronic health record (EHR) transitions are known to be highly disruptive, can drastically impact clinician and staff experiences, and may influence patients' experiences using the electronic patient portal. Clinicians and staff can gain insights into patient experiences and be influenced by what they see and hear from patients. Through the lens of an emergency preparedness framework, we examined clinician and staff reactions to and perceptions of their patients' experiences with the portal during an EHR transition at the Department of Veterans Affairs (VA).

View Article and Find Full Text PDF

Eye infection risks from via hand soap and eye drops.

Appl Environ Microbiol

April 2024

Department of Environmental Science, University of Arizona, Tucson, Arizona, USA.

Eye infections from bacterial contamination of bulk-refillable liquid soap dispensers and artificial tear eye drops continue to occur, resulting in adverse health outcomes that include impaired vision or eye enucleation. (), a common cause of eye infections, can grow in eye drop containers and refillable soap dispensers to high numbers. To assess the risk of eye infection, a quantitative microbial risk assessment for was conducted to predict the probability of an eye infection for two potential exposure scenarios: (i) individuals using bacteria-contaminated eye drops and (ii) contact lens wearers washing their hands with bacteria-contaminated liquid soap prior to placing the lens.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!