PI-RADS version 2.1 (v2.1) modifications primarily address transition zone (TZ) interpretation. The revisions also impact peripheral zone (PZ) interpretation, which has received less attention. The purpose of this study was to compare interobserver agreement of PI-RADS version 2 (v2) and v2.1 in the prostate PZ and TZ and perform a pilot comparison of their diagnostic performance in the two zones. Six radiologists with varying experience retrospectively assessed 80 prostate lesions (40 PZ, 40 TZ) on MRI in separate sessions for PI-RADS v2 and v2.1. Interobserver agreement was assessed using Conger kappa (κ). For 50 lesions with pathology data, average AUC for detecting clinically significant cancer was compared between versions using multireader multicase statistical methods. Error variance and covariance results informed post hoc power analysis. Interobserver agreement for PI-RADS category 4 or greater was higher for version 2.1 (κ = 0.64) than version 2 (κ = 0.51) in the PZ, but similar for version 2 (κ = 0.64) and version 2.1 (κ = 0.60) in the TZ. The PI-RADS v2.1 DWI descriptor "linear/wedge-shaped" had higher agreement than its predecessor version 2 descriptor "indistinct hypointense" (κ = 0.52 vs κ = 0.18) and yielded 14 more true-negative versus five more false-negative interpretations. The ADC signal descriptor "markedly hypointense," for which only version 2.1 provides a specific definition, had lower agreement in version 2.1 (κ = 0.26) than version 2 (κ = 0.52). Modified TZ T2-weighted category 2 descriptors in version 2.1 had fair agreement (κ = 0.21), and agreement for PI-RADS category 2 in the TZ was lower in version 2.1 (κ = 0.31) than version 2 (κ = 0.57). DWI upgraded a TZ lesion category from 2 to 3 in four patients, detecting two additional cancers. Average AUC was not different between versions 2 and 2.1 for the PZ (AUC, 0.81 vs 0.85; = .24) or the TZ (AUC, 0.69 vs 0.69; = .94), though among experienced readers AUC was higher for version 2.1 than version 2 for the PZ (0.91 vs 0.82; = .001). Overall performance comparison had sufficient power (0.8) to detect a 0.085 difference in AUC. Interobserver agreement improved using PI-RADS v2.1 in the PZ but not the TZ. Diagnostic performance improved using version 2.1 only in the PZ for experienced readers. Specific version 2.1 modifications yielded mixed results. The impact of PI-RADS v2.1 in the PZ is notable given the emphasis on version 2.1 TZ modifications. The findings suggest areas in which additional modification could further improve interobserver agreement and performance.

Download full-text PDF

Source
http://dx.doi.org/10.2214/AJR.20.24199DOI Listing

Publication Analysis

Top Keywords

interobserver agreement
24
version
18
pi-rads v21
16
diagnostic performance
12
agreement pi-rads
12
agreement
10
pi-rads
9
transition zone
8
pi-rads version
8
version v21
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!