Purpose: The aim of this study was to investigate the efficacy of shear wave elastography (SWE) in the diagnosis of perforating vein insufficiency, and to determine the applicability of these measurements.

Methods: A total of 140 symptomatic patients with a total of 280 lower extremities were investigated. All patients presented with venous insufficiency (VI) symptoms, and received Doppler ultrasound assessment to determine VI and SWE measurements. The SWE values were measured in the adjacent perivenous tissue of the largest Cockett's perforating vein (PV) of both lower extremities, at the level where they pass the fascia. The Cockett's PV diameter and the presence of reflux in Cockett's PV and the great saphenous vein were compared with SWE values in perivenous tissue of PVs.

Results: The SWE values of the perforating vein insufficiency group were significantly higher than those of the normal PV without insufficiency group (P < 0.001). A significant and positive relation was seen between increased PV diameter and SWE values (P < 0.001) and there was a significant relationship between the presence of perforating vein insufficiency and increase in PV diameter. A statistically significant increase was detected in SWE values for the PV for those with reflux in the great saphenous vein (P < 0.001). The best cut-off values that can be used to detect perforating vein insufficiency were found 34.600 for kPa and 3.375 for m/s.

Conclusion: SWE may be used effectively in addition to conventional Doppler ultrasound examination in diagnosing and following perforating vein insufficiency.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8572307PMC
http://dx.doi.org/10.1007/s40477-020-00527-xDOI Listing

Publication Analysis

Top Keywords

perforating vein
12
swe values
12
venous insufficiency
8
shear wave
8
wave elastography
8
vein insufficiency
8
lower extremities
8
perivenous tissue
8
insufficiency group
8
insufficiency
5

Similar Publications

Objective: CEAP categorizes patients based on disease progression and severity. Whether disease severity is associated with specific patterns of reflux is currently unknown. We hypothesize that patterns of reflux in patients with C2 and C5/6 disease will differ.

View Article and Find Full Text PDF

A Clinical Suspicion That Led to the Diagnosis of May-Thurner Syndrome.

Cureus

December 2024

Family Medicine, USF Progresso e Saúde - Tocha, Cantanhede, PRT.

May-Thurner syndrome is an anatomical anomaly characterized by venous compression of the iliac vein by the arterial system. It is more common in women. It may be asymptomatic or lead to symptoms related to hypertension/venous occlusion, namely, edema of the lower limb.

View Article and Find Full Text PDF

Characteristics of In Vivo Lesion Formation With a Temperature-Controlled Diamond-Tip Radiofrequency Ablation Catheter in the Ventricle: A Preclinical Model.

Circ Arrhythm Electrophysiol

January 2025

Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN (T.H., M.E.R., O.Y., G.N.K., N.O., T.K., L.N., D.L.P., K.C.S.).

Background: Power-controlled radiofrequency ablation with irrigated-tip catheters has been the norm for ventricular ablation for almost 2 decades. New catheter technology has recently integrated more accurate tissue temperature sensing enabling temperature-controlled irrigated ablation. We aimed to investigate the in vivo ablation parameters and lesion formation characteristics in ventricular myocardium using a novel temperature-controlled radiofrequency catheter.

View Article and Find Full Text PDF

The introduction of devices for endovascular dialysis access creation (WavelinQ and Ellipsys) offers practitioners more options for access management in dialysis patients. Especially in terms of reducing the usage of central venous catheters, a native fistula is desirable as an initial dialysis access. We present a case in which a failed WavelinQ type fistula was reactivated using the Ellipsys procedure on the same arm.

View Article and Find Full Text PDF

Predictive Factors of a Dominant Superficial Venous Drainage System in DIEP Flap Surgery With Preoperative Computed Tomography Angiography.

Microsurgery

January 2025

Service de Chirurgie Plastique, Hôpital Européen Georges Pompidou, Assistance Publique-Hôpitaux de Paris (APHP), Université Paris Descartes, Paris, France.

Background: Venous congestion due to superficial venous system dominance (SVD) in deep inferior epigastric perforator (DIEP) flap surgery occurs in approximately 2% of cases, with attendant sequelae and increased cost to healthcare systems. This study aimed to describe the predictive factors for SVD in DIEP flap breast reconstruction based on preoperative computed tomography angiography (CTA) findings.

Methods: All women who required takebacks for additional venous anastomosis to the cephalic vein because of SVD after DIEP flap breast reconstruction between 2015 and 2022 were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!