The aim of this study was to evaluate the effect of 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) on bond strength of fiberglass posts in root canals obturated with different endodontic sealers. Seventy-eight mandibular premolars were obturated with three sealers (n=26): Endofill (END), AH Plus (AHP), and Endosequence BC Sealer (EBS). After preparation of the post space, two subgroups were formed according to the cementation of the posts (n=13): with EDC (EDC), and without EDC (control - CON). The specimens were submitted to a pull-out test, failure mode classification, and root canal surface evaluation by scanning electron microscopy after post displacement. Regarding the bond strength, a significant difference between the EDC and CON subgroups occurred only in the END (p=0.001). No difference was detected among the CON subgroups (p=0.339). However, among the EDC subgroups, AHP presented significantly higher values (END versus AHP: p=0.001; AHP versus EBS: p=0.016). Upon classification of failure modes, score 1 (≥ 50% of cement) was the most commonly observed, except for the END + EDC. Remains of endodontic sealers and resin cements were found in the cervical third, but without statistical difference (p=0.269), while in the middle third, difference occurred (p=0.004). In conclusion, EDC decreases bond strength when associated with END sealer, without changing the failure mode between the resin cement and fiberglass post. The best performance was observed when EDC was combined with AHP sealer.

Download full-text PDF

Source
http://dx.doi.org/10.1590/0103-6440202002897DOI Listing

Publication Analysis

Top Keywords

bond strength
12
edc
9
1-ethyl-3-3-dimethylaminopropyl carbodiimide
8
endodontic sealers
8
edc edc
8
failure mode
8
con subgroups
8
observed edc
8
ahp
5
effects 1-ethyl-3-3-dimethylaminopropyl
4

Similar Publications

Self-healing optically transparent polyimides have potential applications in optoelectronic device fabrication. In this study, for the first time, we successfully prepared a novel self-healing polyimide film containing reversible disulfide bonds through chemical imidization by introducing cystamine as a self-healing functional monomer into the molecular structure of conventional polyimides. The incorporation of cystamine enabled the films to maintain high transmittance (>87%) and tensile strength (>99 MPa).

View Article and Find Full Text PDF

The structural adhesive bonding of aluminum is widely used in the aircraft and automotive industries. The surface preparation of aluminum prior to adhesive bonding plays a significant role in improving the bonding strength. Surface cleanliness, surface roughness, and surface chemistry can be controlled, primarily, by proper surface treatment methods.

View Article and Find Full Text PDF

In the work presented here, we explore the upcycling of polyethylene terephthalate (PET) that was derived from water bottles. The material was granulated and extruded into a filament compatible with fused filament fabrication (FFF) additive manufacturing platforms. Three iterations of PET combined with a thermoplastic elastomer, styrene ethylene butylene styrene with a maleic anhydride graft (SEBS-g-MA), were made with 5, 10, and 20% by mass elastomer content.

View Article and Find Full Text PDF

(1) Background: Alkasite is a novel restorative material that has attracted interest in recent years because of its distinctive characteristics, including its high translucency and excellent biocompatibility. It is comparable to glass ionomer cement (GIC) and resin-modified glass ionomer cement (RMGIC) due to its fluoride-release ability and usage in esthetically concerned areas. This study aimed to assess the shear bond strength (SBS) of Alkasite restorative material in comparison with GIC and RMGIC (2) Methods: The study sample included 120 extracted sound primary molars and was randomly split into three groups, including group 1: RMGIC; group 2: Alkasite; and group 3: GIC.

View Article and Find Full Text PDF

Interaction Between Concrete and FRP Laminate in Structural Members Composed of Reused Wind Turbine Blades Filled with Concrete.

Materials (Basel)

December 2024

Department of Building Structures and Structural Mechanics, Faculty of Civil Engineering and Environmental Sciences, Bialystok University of Technology, Wiejska 45A, 15-351 Bialystok, Poland.

The lifecycle of wind turbine blades is around 20-25 years. This makes studies on the reuse of dismantled blades an urgent need for our generation; however, their recycling is very difficult due to the specific makeup of their composite material. In this study, the authors determined a concept for the reuse of turbine blade sections filled with concrete for geotechnical structures, retaining the walls, piles, or parts of their foundations.

View Article and Find Full Text PDF