The aim of this study was to evaluate the influence of different coronal preflaring protocols (absent, conservative and conventional) on the accuracy of Root ZX II, Raypex 6, and RomiApex A-15 electronic foramen locators (EFLs). Twenty mandibular molars with Vertucci's type IV mesial roots were subjected to endodontic exploration and foraminal patency confirmation. Under 16x magnification, its real lengths (RL) were measured and registered (RL1). The canals were then irrigated with 2.5% sodium hypochlorite and electronically measured (EM1) employing the alginate model; all measurements were performed in triplicate by a blind operator using adjusted endodontic hand-files introduced until the apex foramen. Coronal preflaring procedures were sequentially performed with #25/.06 (conservative) and #25/.12 (conventional) instruments; new RLs extents were performed after each coronal preparation protocol (RL2/RL3), as same as electronic measurements (EM2/EM3). The devices error (mm) was evaluated considering the difference between RLs and EMs at each preparation stage; their precision was stablished adopting ±0.5 mm as tolerance margin. The EFLs error significantly reduced after conventional coronal preflaring protocol (p<0.05), which not occur after the conservative one. The best precisions values were noted after conventional preparation as 90% (Root ZX II), 97.5% (Raypex 6), and 92.5% (RomiApex A-15). No significant differences were found in EFLs comparisons, regardless of the coronal protocol tested (p>0.05). Under the conditions tested it can be concluded that the EFLs evaluated were precise. Moreover, the preflaring protocols influences its accuracy's, where the less conservative one produced the best results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1590/0103-6440202003282 | DOI Listing |
Dent J (Basel)
August 2024
Faculty of Medicine and Pharmacy, University of Oradea, 410 087 Oradea, Romania.
Cureus
March 2024
Conservative Dentistry and Endodontics, Sree Anjaneya Institute of Dental Sciences, Kozhikode, IND.
Background And Objectives: The initial size of a root canal is established by progressively introducing K-files according to the increase in the International Organization for Standardization (ISO) size in the apical region. The initial file-fit sensation is caused by coronal interferences rather than always occurring at the apex, as is commonly believed. Flaring the canal at its earliest stages enables the practitioner to accurately assess the size of the canal approaching the apex.
View Article and Find Full Text PDFF1000Res
November 2023
Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam, 31411, Saudi Arabia.
Successful root canal treatment is influenced by the apical extent of root canal preparation and the eventual root canal filling. Achieving the full working length until the apical constriction, which is usually 0.5 - 1 mm shorter than the anatomical apex, is crucial.
View Article and Find Full Text PDFJ Endod
December 2023
Department of Endodontics, Faculty of Dentistry, Van Yüzüncü Yıl University, Van, Turkey.
Introduction: The aim of this study was to investigate the effect of using coronal preflaring file (One Flare; OF) with rotational (One Curve; OC) and reciprocal (WaveOne Gold; WOG) single file systems on postoperative pain in mandibular premolar teeth with symptomatic irreversible pulpitis.
Methods: Eighty patients were included in this prospective, superiority, parallel, and randomized controlled clinical trial. The patients were randomly divided into four groups (n = 20) based on the use of coronal preflaring and the kinematics of the shaping instrument: WOG (without coronal preflaring), WOG with coronal preflaring (OF), OC (without coronal preflaring), and OC with coronal preflaring (OF).
J Pharm Bioallied Sci
July 2023
Department of Conservative Dentistry and Endodontics, AB Shetty Memorial Institute of Dental Sciences, Nitte (Deemed to be University) Derlakatte, Mangaluru, Karnataka, India.
Background And Objectives: The aim of this study was to see the incidence of cracks in root dentin after coronal flaring using various rotary instruments such as Gates Glidden (GG) drills, ProTaper Universal SX, OneFlare, and HyFlex EDM.
Materials And Methods: Seventy freshly extracted premolar teeth with single canal were collected. All the teeth were randomly divided into five groups of fourteen each ( = 14), of which one group served as the control and the rest of the four groups were instrumented with GG drills, ProTaper Universal SX, OneFlare, and HyFlex EDM, respectively.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!