Mechanically stable specific heterodimerization between small protein domains have a wide scope of applications, from using as a molecular anchorage in single-molecule force spectroscopy studies of protein mechanics, to serving as force-bearing protein linker for modulation of mechanotransduction of cells, and potentially acting as a molecular crosslinker for functional materials. Here, we explore the possibility to develop heterodimerization system with a range of mechanical stability from a set of recently engineered helix-heterotetramers whose mechanical properties have yet to be characterized. We demonstrate this possibility using two randomly chosen helix-heterotetramers, showing that their mechanical properties can be modulated by changing the stretching geometry and the number of interacting helices. These helix-heterotetramers and their derivatives are sufficiently stable over physiological temperature range. Using it as mechanically stable anchorage, we demonstrate the applications in single-molecule manipulation studies of the temperature dependent unfolding and refolding of a titin immunoglobulin domain and α-actinin spectrin repeats.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7479118 | PMC |
http://dx.doi.org/10.1038/s41467-020-18323-w | DOI Listing |
ACS Nano
January 2025
Soft Foundry Institute, Seoul National University, Seoul 08826, Republic of Korea.
Nickel-rich NCM cathode materials promise lithium-ion batteries with a high energy density. However, an increased Ni fraction in the cathode leads to complex phase transformations with electrode-electrolyte side reactions, which cause rapid capacity fading. Here, we show that an initial formation cycle at 0.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
January 2025
Beijing University of Chemical Technology, State Key Laboratory of Organic-Inorganic Composites, 15 North Third Ring Road East, 37830, Beijing, CHINA.
Polymers with strong electron-withdrawing groups (e.g., cyano-containing polymers) are attractive for a wide range of applications due to their high dielectric constant and outstanding electrochemical stability.
View Article and Find Full Text PDFRev Sci Instrum
January 2025
Hangzhou Huger Medical Robotics Co., Ltd., Hangzhou 310002, Zhejiang, People's Republic of China.
A novel robust control strategy is proposed in this work to address the dynamic control problem of permanent magnet synchronous motors (PMSM) position tracking and lessen the effect of system parameter and load fluctuations on the dynamic performance of PMSM. The tracking performance is improved by a robust control element built with the Lyapunov method to reduce the impact of uncertain factors such as parameter uncertainty, nonlinear friction, and external interference; the nominal control element is stabilized by the dynamics model. The uniformly bounded and uniformly final bounded systems are proven, and the associated conclusions are provided using the Lyapunov minimax approach.
View Article and Find Full Text PDFJ Chem Inf Model
January 2025
Molecular Simulations and Design Group, Max Planck Institute for Dynamics of Complex Technical Systems, Sandtorstrasse 1, 39106 Magdeburg, Germany.
Cezanne-2 (Cez2) is a deubiquitinylating (DUB) enzyme involved in the regulation of ubiquitin-driven cellular signaling and selectively targets Lys11-linked polyubiquitin chains. As a representative member of the ovarian tumor (OTU) subfamily DUBs, it performs cysteine proteolytic isopeptide bond cleavage; however, its exact catalytic mechanism is not yet resolved. In this work, we used different computational approaches to get molecular insights into the Cezanne-2 catalytic mechanism.
View Article and Find Full Text PDFPurpose Of The Study: Intraarticular fractures of the distal femur rank among the most severe musculoskeletal injuries. Various treatment options, such as plate osteosynthesis or retrograde nailing, can be employed. This study aims to evaluate the clinical outcomes and complications of intraarticular distal femoral fractures treated with retrograde femoral nail, with particular emphasis on C3 fractures.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!