In vascular surgery, most synthetic vascular grafts currently used for large vessels replacements are made of Dacron (polyethylene terephthalate; PET). In this study, the dynamic response of these synthetic arterial substitutes to physiological pulsatile conditions is investigated in depth. Experiments were performed on a mock circulatory loop developed to replicate physiological pulsatile pressure and flow. Two different models of Dacron grafts (branched and straight) were tested at various heart rate conditions. Results are presented in terms of cyclic axisymmetric diameter changes, hysteretic loops of the pressure-diameter change, and viscoelastic parameters, such as loss factor and storage modulus that are identified from the hysteresis loop. The amplitude of cyclic diameter change of the Dacron graft was found to be always below 0.2% for all the heart rates considered (from 57 to 187 bpm). The loss factor of the Dacron graft slightly increased with the heart rate; almost no effect of the pulse rate was observed on the storage modulus, which was identified to be around 100 MPa. Both glycerol-water mixture (i.e. the blood analogue fluid) and saline solution were used in the circulatory loop and results did not present significant differences between the two cases. This shows that the effect of the shear load on the dynamic response of Dacron grafts is negligible. A comparison between Dacron vascular implants and human thoracic aortas shows a large mismatch in their viscoelastic mechanical properties.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2020.103804DOI Listing

Publication Analysis

Top Keywords

physiological pulsatile
12
dynamic response
8
circulatory loop
8
dacron grafts
8
heart rate
8
loss factor
8
storage modulus
8
modulus identified
8
dacron graft
8
dacron
7

Similar Publications

Advanced Markers for Hemodynamic Monitoring in Cardiogenic Shock and End-Stage Heart Failure: A Mini Review.

Heart Fail Rev

January 2025

Division of Cardiovascular Medicine, University of Utah Health & School of Medicine, 30 N Mario Capecchi Drive, HELIX Building 3rd Floor, Salt Lake City, UT, 84112, USA.

Right heart catheterization (RHC) provides critical hemodynamic insights by measuring atrial, ventricular, and pulmonary artery pressures, as well as cardiac output (CO). Although the use of RHC has decreased, its application has been linked to improved outcomes. Advanced hemodynamic markers such as cardiac power output (CPO), aortic pulsatility index (API), pulmonary artery pulsatility index (PAPi), right atrial pressure to pulmonary capillary wedge pressure ratio (RAP/PCWP) and right ventricular stroke work index (RVSWI) have been introduced to enhance risk stratification in cardiogenic shock (CS) and end-stage heart failure (HF) patients.

View Article and Find Full Text PDF

Dobutamine-induced alterations in internal carotid artery blood flow and cerebral blood flow in healthy adults.

Brain Res Bull

January 2025

Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China; Precision and Intelligence Medical Imaging Lab, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China. Electronic address:

Purpose: Dobutamine, a sympathomimetic agent, is widely used clinically, influencing cardiac output, heart rate (HR), and blood pressure (BP), which may impact cerebral blood flow (CBF), critical for brain metabolism. However, the effects of dobutamine on CBF and internal carotid artery (ICA) blood flow remain unclear, with contradictory reported in both clinical and animal studies. It is necessary to investigate the effects of dobutamine on cervical and cerebral hemodynamics.

View Article and Find Full Text PDF

Background: Direct mechanical ventricular actuation (DMVA) with the Anstadt cup is effective for non-blood-contacting biventricular support. Pneumatic regulation of a silicone device augments ventricular pump function. Vacuum attachment facilitates diastolic augmentation critical for biventricular support.

View Article and Find Full Text PDF

Aneurysm dome and vessel pressure measurements with coiling, stent assisted coiling and flow diversion.

Acta Neurochir (Wien)

January 2025

Division of Neurosurgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis Street , Boston, MA, 02215, USA.

Background: Variability in long-term endovascular treatment outcomes for intracranial aneurysms has prompted questions regarding the effects of these treatments on aneurysm hemodynamics. Endovascular techniques disrupt aneurysmal blood flow and shear, but their influence on intra-aneurysmal pressure remains unclear. A better understanding of aneurysm pressure effects may aid in predicting outcomes and guiding treatment decisions.

View Article and Find Full Text PDF

The effect of acetazolamide on regional brain tissue oxygenation in patients with acute brain injury (ABI) is unknown. We studied adult patients with ABI who received acetazolamide as per the treating physician's decision and had ICP and brain oxygen pressure (PbtO) monitoring. Baseline measurements of ICP, cerebral perfusion pressure (CPP), and PbtO were taken before administering acetazolamide; subsequent measurements were recorded every 5 min for a total of 20 min.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!