Objective: To compare the effects of different materials for partial sciatic nerve ligation on glial cell activation in the spinal cord in a rat model of chronic constriction injury (CCI).

Methods: SD rats were randomly divided into the sham group (=15), silk suture CCI group (=15) and chromic catgut CCI group (=14). The mechanical withdrawal threshold (MWT) and thermal withdrawal latency (TWL) of the rats were detected at 3, 7, 11 and 15 days after the operation. The changes in the sciatic nerve, the activation of spinal cord glial cells and the expression of inflammatory factors were observed using Western blotting and RT-PCR.

Results: At 3 to 15 days after the surgery, MWT and TWL of the rats were significantly lower in silk suture group and chromic catgut group than in the control group ( < 0.05), and was significantly lower in chromic catgut group than in the silk suture group ( < 0.05) at 3 days after the surgery. The results of sciatic nerve myelin staining showed that the sciatic nerve was damaged and demyelinated in both the ligation groups. The expressions of CD11b, GFAP, IL-1β and TNF-α in the two ligation groups were similar and all significantly higher than those in the control group ( < 0.05). IL-6 mRNA level was significantly higher in chromic catgut group than in the silk suture group ( < 0.05).

Conclusions: The CCI models established by partial sciatic nerve ligation with silk suture and chromic catgut all show glial activation, and the inflammatory response is stronger in chromic catgut group.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7429167PMC
http://dx.doi.org/10.12122/j.issn.1673-4254.2020.08.20DOI Listing

Publication Analysis

Top Keywords

sciatic nerve
24
chromic catgut
24
silk suture
20
catgut group
16
partial sciatic
12
nerve ligation
12
group
12
suture group
12
group 005
12
materials partial
8

Similar Publications

While silk fibroin (SF) obtained from silkworm cocoons is expected to become a next-generation natural polymer, a fabrication method for SF-based artificial nerve conduits (SFCs) has not yet been established. Here, we report a bioresorbable SFC, fabricated using a novel freeze-thaw process, which ensures biosafety by avoiding any harmful chemical additives. The SFC demonstrated favorable biocompatibility (high hydrophilicity and porosity with a water content of > 90%), structural stability (stiffness, toughness, and elasticity), and biodegradability, making it an ideal candidate for nerve regeneration.

View Article and Find Full Text PDF

Temporal properties of transcutaneous direct current motor conduction block.

J Neural Eng

January 2025

Physical Medicine and Rehabilitation, The MetroHealth System, 2500 Metrohealth Dr, Cleveland, OH 44109, USA, Cleveland, Ohio, 44109-1998, UNITED STATES.

Direct current (DC) electrical block of peripheral nerve conduction shows promise for clinical applications to treat spasticity, pain, and cardiac arrhythmias. Most previous work has used invasive nerve cuffs. Here we investigate the potential of non-invasive transcutaneous direct current motor block (tDCB).

View Article and Find Full Text PDF

Intradermal Advanced Glycation End-products Relate to Reduced Sciatic Nerve Structural Integrity in Type 2 Diabetes.

Clin Neuroradiol

January 2025

Department of Endocrinology, Diabetology, Metabolic Diseases and Clinical Chemistry (Internal Medicine 1), Heidelberg University Hospital, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany.

Background: Cardiovascular risk management is beneficial, but stringent glycemic control does not prevent the progression of distal sensorimotor polyneuropathy (DSPN). Persistent hyperglycemia-induced alterations and cardiovascular factors may contribute to diabetes-associated nerve damage. This study aimed to evaluate the correlation between skin auto-fluorescence (sAF), an indicator of dermal advanced glycation end-product (AGE) accumulations, cardiovascular risk, and changes in peripheral nerve integrity.

View Article and Find Full Text PDF

Postpartum pyogenic sacroiliitis masquerading as sciatic neuropathy.

BMJ Case Rep

January 2025

Department of Orthopedics, SDM College of Medical Sciences and Hospital, Shri Dharmasthala Manjunatheshwara University, Dharwad, Karnataka, India.

Low back pain is common in women, especially during pregnancy and puerperium. Septic sacroiliitis, a rare cause of back pain in the postpartum period can mimic other common causes of low back pain like muscle strain, urinary tract infection, pelvic inflammatory disease, endometritis and intervertebral disc prolapse. The proximity of the sacroiliac joint to the sacral nerve plexus results in septic sacroiliitis frequently presenting with symptoms mimicking intervertebral disc prolapse.

View Article and Find Full Text PDF

Ex vivo electrophysiological evaluation of peripheral nerve functioning following exposition of adult mice to the organophosphorus pesticide chlormephos.

Environ Toxicol Pharmacol

January 2025

Université Paris-Saclay, CEA, Institut des sciences du vivant Frédéric Joliot, Département Médicaments et Technologies pour la Santé (DMTS), Service d'Ingénierie Moléculaire pour la Santé (SIMoS), EMR CNRS/CEA 9004, 91191 Gif-sur-Yvette, France. Electronic address:

The organophosphorus pesticide chlormephos was tested for its potential peripheral neurotoxicity by analyzing the diphasic compound action potential (CAP) of sciatic nerves isolated from adult mice chronically exposed to a sub-lethal dose of this pesticide, compared with control age-matched animals being only exposed to the vehicle. No significant modification was detected between chlormephos-exposed and control groups in their nerve responsiveness to stimulus. Furthermore, similar values of CAP kinetic variables were obtained from the two mouse groups.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!