Aims: We aimed to assess the safety and efficacy of the DynamX Novolimus-Eluting Coronary Bioadaptor System, a novel device that initially acts as a second-generation drug-eluting stent, but after six months frees the vessel through uncaging elements.
Methods And Results: This multicentre study enrolled 50 patients with single de novo lesions. In-device acute lumen gain was 1.61±0.34 mm, and device and procedure success was 100%. Up to 12 months, two target lesion failures occurred: both were cardiac deaths (day 255 and day 267 post procedure). No definite or probable device thrombosis was observed. Mean late lumen loss was 0.12±0.18 mm in-device and 0.11±0.16 mm in-segment. Per intravascular ultrasound, the mean device area and mean vessel area increased significantly by 5% and 3%, respectively, while the mean lumen area was maintained. Stationary optical coherence tomography in seven patients demonstrated restoration of cyclic pulsatility, with an approximate lumen area variance of 11% between systole and diastole.
Conclusions: The DynamX bioadaptor showed drug-eluting stent-like acute performance and safety and efficacy up to one year. Positive remodelling with an increase of vessel and device area while maintaining the mean lumen area was demonstrated. Long-term follow-up and randomised trials are required to assess the benefit of this device on events beyond one year.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.4244/EIJ-D-20-00763 | DOI Listing |
CVIR Endovasc
December 2024
Department of Cardiovascular Medicine, Osaka Metropolitan University Graduate School of Medicine, 1-4-3 Asahimachi Abenoku, Osaka, 545-8585, Japan.
Background: Fractional flow reserve (FFR) can be estimated by analysis of intravascular imaging in a coronary artery; however, there are no data for estimated FFR in an extremity artery. The aim of this concept-generating study was to determine whether it is possible to estimate the value of peripheral FFR (PFFR) by intravascular ultrasound (IVUS) analysis also in femoropopliteal artery lesions.
Methods: Between April 2022 and February 2023, PFFR was measured before endovascular therapy in 31 stenotic femoropopliteal artery lesions.
J Vasc Interv Radiol
December 2024
Vascular and Interventional Radiology Translational Research Lab, Mayo Clinic, Rochester, MN, USA; Department of Radiology, Mayo Clinic, Rochester, MN, USA. Electronic address:
Purpose: Describe the immunohistologic changes in arteriovenous fistula (AVF) stenosis treated using plain old balloon angioplasty (POBA) versus paclitaxel drug-coated balloons (DCB) MATERIALS AND METHODS: Castrated male Yorkshire pigs (n = 12) 4-5 months old had chronic kidney disease (CKD) induced with renal artery embolization. Twenty-eight days later, a side-to-end anastomosis was created between the left common carotid artery to ipsilateral external jugular vein. Four weeks later, a juxta anastomotic stenosis was treated with balloon angioplasty (PTA) or DCB and animals euthanized at 4 [POBA (n=6)] and 42 days [POBA (n=3) or DCB (n=3)] for histomorphometric analysis with immunohistochemical staining for CD-68 (macrophages), FSP-1 (fibroblasts), α-SMA (smooth muscle cells, SMCs), CD-31 (endothelial), proliferation (Ki-67), and apoptosis (TUNEL).
View Article and Find Full Text PDFSmall
December 2024
Biomaterials and Sensors Laboratory, Department of Physics, Ch. Charan Singh University, Meerut, Uttar Pradesh, 250004, India.
Z-scheme CeO-TiO@CNT (CTC) heterojunction is fabricated using hydrothermal method and evaluated for removing mixed pollutants (MIX-P) from ciprofloxacin (CPF) and textile contaminations. CTC demonstrated ≈99% removal efficiency against MIX-P under solar irradiation of ≈10 lumens. High removal efficiency of CTC is attributed to reduced bandgap (E), 2.
View Article and Find Full Text PDFACS Pharmacol Transl Sci
December 2024
School of Biotechnology, Badr University in Cairo (BUC), Badr City, Cairo 11829, Egypt.
Despite the prevalent utilization of antidepressant combinations in clinical settings, concerns persist regarding heightened side effects and potential drug-drug interactions (DDI). In response, this study investigates the interaction between citalopram (CIT) and duloxetine (DUL) using a multifaceted approach encompassing analytical, computational, behavioral, and biochemical techniques. Notably, the absence of published analytical methods tailored for studying antidepressant interactions underscores the novelty of our endeavor.
View Article and Find Full Text PDFJ Dent Anesth Pain Med
December 2024
Department of Dental Anesthesiology, Ohu University, School of Dentistry, Fukushima, Japan.
Background: In recent years, dexmedetomidine (DEX) has been proposed as a useful vasoconstrictor for local anesthesia because it is less effective in circulation than clonidine of antihypertensive drugs. In addition, DEX is expected to act as a vasoconstrictor during local anesthesia. However, histomorphometric studies demonstrating that DEX exerts vasoconstrictive effects are lacking.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!